SLA (Slave)
To be used to set:
• remotely, with other Easy devices, the type (heating/air
conditioning) and the HVAC operating mode of the timed
thermostat. Examples of devices that can be used include
the Easy GSM remote control, the Easy command and
display panel, the Easy channel interface 4, etc;
• the timed thermostat OFF mode, with priority over all
other commands, in the case of an open window detected
by a remote device. When the closed window is signalled,
the timed thermostat will return to the operating mode it
was prior to the last command received during OFF
forcing;
• the storage/reproduction of max. 8 scenes. The timed
thermostat stores the HVAC operating mode and type.
STS (Status)
To be used to send the following to the remote devices (for
example the Easy thermostat, the Easy GSM remote control,
etc.):
• operating type and HVAC mode;
• measured temperature (every 15 minutes or upon every
variation).
CDH (Heating command)
To be used to send the On/Off command to the Easy
actuators that control the heating or heating/air conditioning
system solenoid valve.
CDC (Air conditioning command)
To be used to send the On/Off command to the Easy
actuators that control the air conditioning system solenoid
valve.