USER INSTRUCTIONS
48
To avoid continuous switchings, the thermostat will wait
for up to 2 minutes before sending the activation
command to the actuator that controls the thermal
regulation system or to the actuator channels that control
the fan coil speed.
P06 - Setting the cycle time
When the P06 code appears on the screen, set the cycle
time using the
keys.
The values available are as follows:
5, 10, 20, 30, 40, 50,
60 minutes.
It is possible to set different cycle times for the heating
and air-conditioning operations. Press the
key within
30 seconds to confirm the value set.
P07 - Setting the PWM regulation differential value
When the P07 code appears on the screen, set the PMW
regulation differential value using the
keys.
It is possible to set different PWM values for the heating
and air-conditioning operations.
Press the
key within 30 seconds to confirm the value
set.
Move on to point P09.
P08 - Setting the regulation differential for 2 point or
fan coil control
When the
, symbol appears on the screen, set the
regulation differential time using the
keys.
Press the
key within 30 seconds to confirm the value
set.
The regulation differential is the deviance between the
set-point setting and the actual activation temperature.
It is possible to set different regulation differentials for the
heating and air-conditioning operations.
It is recommended to retain the preset values except in
special situations.