USER MANUAL | EG-7240 Digital Wireless Conference System

USER MANUAL | EG-7240 Digital Wireless Conference System

08

B

.

Operation Procedure

(

1

)

Set the camera type & address, then connect camera with main controller.

(

2

)

Enter above interface.

(

3

)

Set “type”, “address” & “preset” in the camera tab. Normally, no need to set “baud 

rate”.

(

4

)

After above setting, enter “tracking” tab.

(

5

)

Rotate & zoom the camera to a certain position. In the meantime, the mic loop light 
of tracked unit is flashing.

(

6

)

After setting, click “Save” to save the tracking position. Then unit/preset will plus 1 
automatically for another tracking point setting.

(

7

)

Click “Test” to check preset point. 

8.6 Parameter setting.

Parameter  setting  can  be  saved  as  group  in  this  menu.  Groups  can  be  loaded  to  the 

current system.

There  are  8  groups  can  be  saved  in  one  main  controller.  Each  group  included  below 

parameters:  “Meet  Mode”,  “Tracking  mode”  “Speaking  QTY”,  “Time  Off”,  “Volume”, 

“Capacity”.

Use “Restore to Preset”, to go back to default setting as below:

 Meet Mode: FIFO

Tracking Mode: auto

 

Speaking QTY: 3

Time Off: 000

 Volume: 24

 Capacity: 020

Group Setup

Current Parameter

:

Meet Mode: FIFO

Tracking Mode:Auto

Speaking QTY

:

3

Time Off

003

Volume

21

Capacity

010

Save

Load

Restore to Preset

Exit

Notice:
a.There is no “Channel” in group.
b

.

Only those saved groups can be loaded, otherwise, system will prompt “group invalid”

c

.

Be  careful  about  the  system  capacity  when  loading  group  or  restore  factory  setting. 

Modify system capacity according to the actual amount of units.

8.7  System Info

  To  check  technical  specification  of  main 

controller.

8.8 Advanced setting

Interface of advanced setting.

8.8.1 Edit Address

System must be edited address before first used.
Description:
a Unit: address for the current applying unit.

.

b Channel:  The  channel  for  current  applying  unit.  After  finishing  “edit  address”,  system 

.

will enter this channel

 Current Capacity: current system's capacity. System will keep the last capacity. If the total 

number  of  edited  address  units  is  beyond  last  system  capacity,  system  will  modify  the 
current capacity accordingly.

All the units of the same channel will be controlled to enter “Edit Address” interface.

Set “unit” and “channel”, then wait for unit's address applying.

Press the on/off button on the units in order to obtain address.

Notice:

If  there  are  units  not  in  interface  of  “Edit  Address”  (could  be  because  of  different 

channels),  these  units  can  be  manually  set  to  enter  “Edit  Address”  according  to 
below unit menu instruction.

Chairman unit must be edited “001”, so that it's priority function can be carried out.

Try  not  to  manually  modify  “unit”  and  “channel”  after  editing  address  started. 

Otherwise, it may cause error.

Advanced Setup

Edit Address

Detect 
Channel

Shift 
Channel

Central 
Controller 
Code

Exit

Edit Address

Press Mic to Apply

...

Exit

Unit

001

Channel

: 04

Current Capacity

:010

Max. Capacity

:127

System Info

Exit

Hardware: 00

 

Software:02

 

Current Channel:03

 

Current Capacity:001

Max.Capacity:127

Содержание EG-7240

Страница 1: ...X Y Digital Wireless Conference System EG 7240 USER MANUAL ...

Страница 2: ...11 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provide plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 12 Protect the power co...

Страница 3: ... comply with the Direc ve 2012 19 EU of the European Parliament on waste electrical finance the cost of treatment and recovery of electronic equipment WEEE in order to reduce the amount of WEEE that is being disposed of in land fill site All of our products are marked with the WEEE symbol this indicates that this product must NOT be disposed of with other waste Instead it is the user s responsibilit...

Страница 4: ...then pull the antenna to about 45 angle Power supply AC110 220V To get the best communication the minimum installation height to the ground shall be 1m the minimum distance between launch antenna receiving antenna shall be 2m the minimum distance to wall shall be 1m Keep antennas away from interference such as computer digital equipment TV also big metal item Try to avoid putting barrier in betwee...

Страница 5: ... 10 11 12 9 Product overview 7 Charger unit POWER SWITCH AC POWER SOCKET CHARGING OUTPUT POWER 6V IN Charger unit supports charging 40 microphone units at a time User should switch OFF the microphone units and connect the charging port of microphone units to the DC ports with supplied charging cable Charging time is approx 4 5 hours 8 Menu of Main Controller Main controller adopts capacitive touch...

Страница 6: ...an speak in the same time 1 chairman 3 delegates Time Off Ÿ To turn off the unit compulsively by the set certain time 001 999 second 000 mean this function is disable Volume Ÿ To set the volume of main controller output Capacity Ÿ To limit the total amount of online units Ÿ When the unit address is beyond system capacity it can t connect to the system Ÿ For example when set system capacity is 3 sy...

Страница 7: ...out the system capacity when loading group or restore factory setting Modify system capacity according to the actual amount of units 8 7 System Info To check technical specification of main controller 8 8 Advanced setting Interface of advanced setting 8 8 1 Edit Address System must be edited address before first used Description a Unit address for the current applying unit b Channel The channel fo...

Страница 8: ...00 00 00 F5 Xx for Unit 00 for Full View More code Refer to Protocol Table Other Please select Operate EVI D70 YAAN PELCO D PELCO P Camera BRC Z330 Rotate Zoom Save Load Operate Direction Speed Unit 000 Address Preset Central Controller Code Conference Setup Camera Tracking Other Selection Meet Mode Tracking Mode Speaking QTY Time Off Volume Capacity Parameter Conference Setup Camera Tracking Othe...

Страница 9: ...dress Manual Setup System Info Edit Address C u r r e n t S e t t i n g 00 000 CH Addr Press Mic to Apply 1 2 3 4 Edit Address Current Setting 00 000 CH Addr Fail Edit Address Current Setting CH Addr 00 000 Complete CONFIG ABNORMAL CH 00 Addr 000 Opera on Once unit is successfully edited address it will shows as picture System will go back to status interface when exiting edit address menu If fail...

Страница 10: ...t admin 10 2 Meet Control Ÿ Virtual Saloon Allow user to draw the layout of the meeting table pattern the ID relates to the ID assigned to each microphone unit Ÿ Meet Setup User can configure the setup of the system via this panel including Meet mode Delegate QTY Tracking mode Time off Capacity Volume Ÿ Channel Manage Switch ON OFF the microphone operated on each channel 9 3 Second Screen This win...

Страница 11: ...2 Parameters can be selected from SIGN IN SETUP and SECONDARY SCREEN menu accordingly 3 Press Start Sign in to kick off the process operator can see the process message from the PROCEDURE OF SIGN IN window and attendees will see the system message prompted on the display of each microphone unit connected Attendee should press the ENTER button on the microphone to finish the sign in 4 Operator can ...

Страница 12: ... 18 4 Click Start at progress window can commence the voting immediately Voting options will be shown on the display of each microphone unit connected in this process Attendees can press YES NO ABST 1 2 3 4 5 button on their microphone units and pressing Enter to confirm their selection Voting data will collected to the system in real time basis operator can see the number of voted units and remai...

Страница 13: ...ing then the proposal will be considered as a finished voting operator will not be able to re enter the voting process under this proposal but can only view the result of it But if operator press TERMINATE in the middle of this process then the process will be aborted and the proposal can be re selected to enter the voting process System specifica ons 11 System connection Main Controller camera TV ...

Страница 14: ... system 1 Firstly check System Info in the main controller Check the value for channel current capacity Then manually set the unit as the same channel address to be current capacity 1 For example system channel 01 current capacity 30 then unit shall be set as channel 01 address 31 Details refer to 8 5 2 Re edit address for the whole system 1 Modify the capacity of system according to 7 4 2 Set Man...

Отзывы: