Opera on
11
USER MANUAL | EG-7240 Digital Wireless Conference System
USER MANUAL | EG-7240 Digital Wireless Conference System
12
④
System Info.
Config Abnormal: unit can not communicate with main controller due to failed
channel/address.
No Signal: It means the unit lost connection for more than 8 seconds. It will be
automatically turned off.
Under Setting: It means main controller is now being set (tracking, shift channel, check
channel). In this case, units can't be turned on.
⑤
Mic On/Off
⑥
Mic off reason: One of below reason for cutting off unit: chairman priority, time off,
Limited QTY, No response, System Off. It will last for 1.5seconds.
9.2 Main Menu
Below is the main menu of unit. Press “
to move cursor, then
↑↓”
press ENTER.
9.3 Backlight setup
To set backlight time & brightness
Backlight time “0” means no time limitation.
9.4 Edit Address
Notice:
①
Last set channel & address info will be deleted when entering this menu. When go back
without successfully address editing, address will be “000” & channel will be “00”,
then status interface will show “abnormal”.
②
Main controller need to enter “edit address” menu first, so that units can carry out
“edit address” function.
③
Chairman unit can't carry out priority function until it's address is set “001”.
Apply for address by pressing Mic button as picture
①
.
Backlight Setup
Duration
:
0
Brightness
:
9
Menu
Backlight Setup
Edit Address
Manual Setup
System Info
Edit Address
C u r r e n t S e t t i n g :
:
00
:
000
CH.
Addr.
Press “Mic” to Apply
1
2
3
4
Edit Address
Current Setting:
:
00
:
000
CH.
Addr.
Fail
Edit Address
Current Setting:
CH.
Addr.
:
00
:
000
Complete
CONFIG ABNORMAL
CH.
:
00
Addr.
:
000
Opera on
Once unit is successfully edited address, it will shows as picture
③
.
System will go back to status interface when exiting “edit address” menu. If failed to edit
address, unit will show “abnormal” as picture
④
.
9.5 Manual Setup
Manual setting on the unit is auxiliary setting for “edit address”.
Normally using “edit address” on the main controller to edit
address for the whole system is recommended.Operation
Instruction:
Click “
to move cursor, “
to modify value
↑↓”
←→”
9.6 System Info.
“
Channel”, “Address”, “Hardware”, “Software” can be checked.
9.7 Shutdown
Ÿ
Interface for manual
shutdown
Ÿ
Interface for low battery shutdown
Ÿ
Interface for shutdown by main controller
Ÿ
Unit will either be shut down after above three interfaces, or will be turned to
charging interface by the external power supply.
9.8 Charge
Ÿ
In above charging interface, unit can't be carried out any function. Press power
button to go back to menu interface.
Ÿ
①
Unit will show as picture
for a unfinished charging unit. The battery cells keep
increasing.
Ÿ
②
Unit will show as picture
for a finished charging unit. The three battery cells stay
still
System Info
Channel
:
01
Address
:
001
Hardware
:
01
Software
:
02
Charging...
Full
①
②
Manual Setup
Current Setting
:
CH.
Addr.
:
00
:
000
Address
:
Channel
:
002
01
Shutdown
Low Battery
One Key Shutdown
①
②
③
Shutdown
Shutdown