36
The number of pure graphite rings
depends on the size of the equipment.
Make a note of the type and order of the
individual packing rings for their later
re-installation.
Attention!
The packing rings may get damaged.
Make sure you do not damage the
packing rings during installation and
removal.
When installing and removing the
packing rings never use force.Make
sure that the packing rings are
correctly positioned and not skewed.
Position a punch made from aluminium or
copper onto the base bushing (14).
Force the rings out of the stuffing-box packing:
Packing rings (12)
Distance sleeve (13)
Grooved ring (if provided)
Check the stuffing-box chamber and all
dissembled parts for signs of damage.
Replace all worn or damaged parts.
Clean all dirty parts.
Removing the stuffing box in equipment with
pneumatic diaphragm actuator
The body cover must be detached in order to
remove the gland seal.
Removal of the cover is described on page 30.
Remove the union nut (16).
Remove the stuffing box bush (17).
Pull the spindle (8) out of the cover (4).
The number of pure graphite rings
depends on the size of the equipment.
Make a note of the type and order of the
individual packing rings for their later
re-installation.