21
NRG 16-51, NRG 17-51, NRG 19-51 - USA - Installation & Operating Manual -
850692-00
Installation
Installing the NRG 16-51, NRG 17-51, NRG 19-51, step 1
1. Screw the electrode extension
4
into the measuring electrode
1
.
Fig. 11
2. Determine the required measuring length of the electrode.
3. Mark the appropriate length on the electrode extension
4
with a scriber.
4. Unscrew the electrode extension
4
from the electrode
1
and cut it.
5. After a visual inspection, screw the extension
4
firmly into the electrode
1
. Push the retain-
ing spring
3
onto the electrode extension
4
until it is securely seated in the hole
2
.
6. Fit the enlarged measuring surface: Push the washer
6
onto the enlarged measuring surface
in such a way that the surface projects 0.08 in (2 mm) beyond the underside of the washer.
Secure the washer with the set screw
5
in this position. Push the supplied retaining ring
7
over the electrode extension from below onto the washer
6
.
Key
1
Measuring electrode
2
Hole
3
Retaining spring
4
Electrode extension
5
Set screw
6
Washer (enlarged measuring surface)
7
Retaining ring
0
Electrode thread
a
Thermal insulation provided on site,
d=0.8 in (20 mm)
(outside thermal insulation of
steam generating unit)