LRR 1-50, LRR 1-51 - USA - Installation & Operating Manual -
850702-01
Operation, alarm and test
Enabling password protection
Action
Display
Function
Turn rotary knob until PW is
shown.
The display toggles between
the parameter name and the
parameter value.
Parameter is selected.
Press and hold the push-button
(on rotary knob).
PASS
Password entry is required.
Release the push-button, then
press and hold it again.
First digit (000
0
) flashes.
Enter the password, starting with
the digit on the right.
Turn the rotary knob clockwise
or counterclockwise to enter the
required digit.
000X
Enter the first digit.
Briefly press the push-button.
The second digit from the right
flashes (00
0
X).
You can enter the second digit.
Repeat the last two steps until
the password has been entered
in full.
The entered password (XXXX)
is shown
Enter the password in full.
Press and hold the push-button.
donE
The correct password has been
entered. The parameter can be
edited.
FAiL
The wrong password has been
entered. The parameter is still
password-protected.
quit
Timeout. The system returns to
parameter settings. Password entry is
discontinued.
Once disabled, password protection is reactivated after 30 minutes of no activity (i.e., rotary knob is not
turned), and the password must be entered again. The parameters are password-protected when the
equipment is restarted, if password protection was previously enabled.
Password protection
The option of password protection for parameters is available as of software version “S-13”.
The default password is 1902 and cannot be changed.