13
A straight distanceof at least five times the nominal
pipe diameter for stabilizing the flow pattern must
be left upstream of the equipment.
Attention!
Malfunctions may occur if the stabilizing
distance is not sufficient.
Make sure that the distance between
the pump and the equipment is
enough to provide a stabilized flow
pattern.
Installing the equipment with vertical
direction of flow
DANGER
Incorrectly connected equipment can result
in accidents with extremely severe injuries
or death.
Make sure that only specialist
personnel connect the equipment to
the pipe.
Make sure that the direction of flow in
the pipe matches the flow direction
arrow on the equipment.
Make sure that the connected pipe
does not subject the body to any
stress (forces or torques) during
installation and operation.
Specialist personnel must have knowledge and
experience of the type of pipe connection used.
Attention!
If the installation position is incorrect
malfunctions may occur and/or the
equipment or the installation may get
damaged.
Make sure that the equipment is
installed in the correct position.
Mount the equipment downsteam of a
pipe bend.
When installing the equipment make
sure that the eye bolt points towards
the inside of the pipe bend.
The correct position of installation is indicated by
the position of the eye bolt and the flow arrow on
the nameplate.