![Gestetner C7006dw Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/gestetner/c7006dw/c7006dw_printer-reference_2217814063.webp)
Printer Does Not Print
51
4
Is the
Data In
indicator
blinking or lit after start-
ing the print job?
If the
Data In
indicator stays off, data is not being sent to
the printer or the printer may be resetting the print job be-
cause there was a long delay in receiving the data from
the computer.
❖
If the printer is using "I/O Timeout"
Increase the value of the "I/O Timeout" setting of the
"IPDL-C Menu" or "RPS2 Menu". Or set the "I/O Tim-
eout" value to "0" (this is the off setting).
⇒
P.83
“Using
the Operation Panel”
❖
If the printer is connected to the computer using the
parallel cable
Confirm that the printer port settings are correct. For a
parallel port connection, port LPT1 or LPT2 should be
set.
For more information about the printer port settings,
see the notes after this table.
❖
Network connection
Contact your network administrator.
If the
Data In
indicator is blinking or lit.
The printer may be resetting the print job. Take the fol-
lowing steps to correct the situation.
• Increase the "Job Timeout" setting of the "IPDL-C
Menu" or "RPS2 Menu".
• Confirm that the printer driver settings are correct.
• Change the "Transfer" setting in the "System Menu".
• Confirm that the "Parallel" setting in "System Menu" is
correct.
Do you print via a net-
work?
Confirm that the "Ethernet" setting is correct from the op-
eration panel.
⇒
P.88
“Menu Table”
The setting governs the data transfer speed used by the
Network Interface Board. Three options are available:
• Auto (default)
• 100 Mbps
• 10 Mbps
Note
❒
For details about the appropriate setting to use on
your network, contact your network administrator.
Possible cause
Solutions
Содержание C7006dw
Страница 1: ...Operating Instructions Printer Reference...
Страница 12: ...x...
Страница 32: ...Setting Up the Printer Driver and Canceling a Print Job 20 2...
Страница 48: ...Paper and Other Media 36 3...
Страница 94: ...Troubleshooting 82 4...
Страница 126: ...Using the Operation Panel 114 5...
Страница 142: ...130 UE USA G048...
Страница 144: ...S1383 UE USA G048 8627 Type for Savin SLP624s SLP624d C7006d C7006dw SAVIN CORPORATION...