43
GB
4. Technical Data
Type of tool
TAURUS
®
1 C TAURUS
®
2 C TAURUS
®
3 C TAURUS
®
4 C
Weight ca.
2.3 kg
2.4 kg
2.8 kg
2.9 kg
Operating pressure
5-7bar
5-7bar
5-7bar
5-7bar
Stroke
15mm
18mm
25mm
19mm
Air connecting hose Ø
6mm
6mm
6mm
6mm
Spent mandrel container capacity
ca. 100 – 200 spent mandrels acc. To size
Air consumption [l/rivet]
approx. 1,0
approx. 2,3
approx. 4,8
approx.. 4,8
Setting Power at 5 bar
4200N
9000N
14000N
20000N
Hydraulic fluid ISO VG 32 up to 46
approx. 30ml approx. 30ml approx. 30ml approx. 30ml
Noise emissionLpa
77
78
79
79
Vibration
<2.5m/s²
<2.5m/s²
<2.5m/s²
<2.5m/s²
Compressed air requirement (filtered)
Integrated spent mandrel ejection
Integrated rivet retention
Tool
Power supply
24Volt DC (No galvanic separation in the tool)
Permitted supply voltage range
10-30Volt
Power input
1.5Watt
Behavior in case of failure of supply voltage
Automatic data recovery after power failure
Lifetime of support battery (CR2032) for Real time
clock, type.
5 years
Interface
RS232
Transfer rate interface
1200Baud – 115200Baud
Protocol interface
8 data bits, 1 stop bit, parity even
Hardware handshake
CTS/RTS
Process data memory
max. 260000 process data records
Profile data memory
224 profiles in 10 profile lists
Temperature range
0-50°C
Safety class
IP 20
Prozessdatenmodul