P.49
Display
Cause
Solution
E01
Chamber high temperature protection
(temperature in the chamber is higher than
security setting)
Stop working, open oven door for 8-10
minutes, and restart the appli-ance.
E02
Evaporator high temperature protection
(temperature in evaporator is higher than
security setting)
Stop working, wait for 8-10 minutes, and
restart the appliance.
E03
Chamber low temperature protection (the unit
works for 3 minutes under 35°C)
1. Check if drain switch in the chamber
is closed, if not, close it and reboot the
appliance.
2. Contact customer service & re-pair centre.
E04
Evaporator low temperature protection (the
unit works for 3 minutes under 35°C)
Contact customer service & repair centre.
E05
Sensor connection failure (open circuit of
chamber or
evaporator sensor)
Contact customer service & repair centre.
E06
Malfunction of sensor (short circuit of chamber
or
evaporator sensor)
Contact customer service & repair centre.
Alarm Troubleshooting
Care & Maintenance
Specification
Model No.
SGV-5221
Voltage/Frequency
220-240V/50Hz
Rated Power
2,100W
Product Dimension
(H×W×D)
455mm×595mm×550mm
Cavity Size
(H×W×D)
Approx. 225mm×470mm×410mm
Tank Cavity
1.3L
Net weight
32 Kg
Specifications are subject to change without prior notice.