P.45
Care & Maintenance
Clean steam generator
1. Please drain the residual water and water scald in steam generator if the unit will not be used for a
long time. Operation: Pull out drain cock on lower right corner of chamber (Note: Do not forget to block the
drain cock after water in drained).
Rubber Plug handle
Pull out the rubber plug according to the arrow direction to drain waste water in evaporating pan and tube.
Waste water stagnate for too long will become water scald, leading to pipe blockage. After the drainage,
put rubber plug back to avoid water leakage.
Remove shelves
1. Unscrew 4 nuts clockwise on both sides of shelves and then take out shelves.
2. Clean the shelves.
Shelf installation
1. Insert right and left shelf in chamber, screw mating nuts anticlockwise to fix the shelves.