Do not obstruct the ventilation openings. 

• 

Never push objects of any kind into slots or openings on this equipment. 

• 

If any of the following conditions occur, switch off the power to the machine 
immediately and disconnect the power cord from the electrical outlet. Call an 
authorized local service representative to correct the problem. 

− 

The equipment emits an unusual noise or odour. 

− 

The power cord is damaged or frayed. 

− 

A wall panel circuit breaker, fuse, or other safety device has been tripped. 

− 

Liquid is spilled into the folder. 

− 

The equipment is exposed to water. 

− 

Any part of the equipment is damaged. 

 

Disconnect Device 

The power cable is the disconnect device for this equipment.  It is attached to the 
back of the machine as a plug-in device.  To remove all electrical power from 
the equipment, disconnect the power cable from the electrical outlet. 

 

Operational Safety Information 

To ensure the continued safe operation of your GERA equipment, follow these 
safety guidelines at all times. 

Do these: 

• 

Always connect equipment to a correctly grounded power outlet.  If in doubt, 
have the outlet checked by a qualified electrician. 

• 

This equipment must be connected to a protective grounded circuit. This 
equipment is supplied with a plug that has a protective grounding pin.  This 
plug will only fit into a grounded electrical outlet.  This is a safety feature.  
To avoid risk of electric shock, contact your electrician to replace the 
electrical outlet if you are unable to insert the plug into it.  Never use a plug 
that lacks a grounded connection terminal to connect the product to an 
electrical outlet. 

• 

Always follow all warnings and instructions that are marked on or supplied 
with the equipment. 

• 

Always exercise care when moving or relocating equipment.  Please contact 
your local support organization to arrange relocation of the product to a 
location outside your building. 

• 

Always locate the equipment in an area that has adequate ventilation and room 
for servicing. See the Install guide for minimum dimensions. 

• 

Always use materials and supplies specifically designed for your GERA 
equipment.  Use of unsuitable materials may result in poor performance. 

• 

Always unplug this equipment from the electrical outlet before cleaning. 

Do not Do these: 

• 

Never use a plug that lacks a grounded connection terminal to connect the 
product to an electrical outlet. 

• 

Never attempt any maintenance function that is not specifically described in 
this documentation. 

• 

This equipment should not be placed in a built-in installation unless proper 
ventilation is provided. Please contact your Authorized Local Dealer for further 
information. 

• 

Never remove covers or guards that are fastened with screws. There are no 
operator serviceable areas within these covers. 

• 

Never locate the equipment near a radiator or any other heat source. 

• 

Never push objects of any kind into the ventilation openings. 

• 

Never override or “cheat” any of the electrical or mechanical interlock devices. 

• 

Never operate the equipment if you notice unusual noises or odors. Disconnect 
the power cord from the electrical outlet and contact your local Service 
Provider immediately. 
 

Содержание Baby Fold

Страница 1: ...GERA Baby Fold Operator Manual Revision December 2014...

Страница 2: ...TION 4 ENVIRONMENTAL COMPLIANCE 4 WARRANTY 4 GENERAL NOTE 5 FOLD PACKAGE DIMENSION 5 PAPER SPECIFICATION 5 FLOOR SPECIFICATION 5 FOLDER VERSION 5 FOLD PROGRAMS 6 CONTROL PANEL 7 FAN FOLDING PROCEDURE...

Страница 3: ...f you are not sure that your electrical supply meets the requirements please consult your local power company for advice WARNING This product must be connected to a protective grounded circuit This pr...

Страница 4: ...let if you are unable to insert the plug into it Never use a plug that lacks a grounded connection terminal to connect the product to an electrical outlet Always follow all warnings and instructions t...

Страница 5: ...operate this equipment Product Safety Certification This product is certified by following the Safety standards EN60950 Regulatory Information The CE mark applied to this product symbolizes GERA s de...

Страница 6: ...ds a poor quality and increases a folding jams All types of paper different from the common must not be folded Mylar or polyester film must not enter the folder as they can also cause jams and damage...

Страница 7: ...TRIC Step 1 Fan Fold 210mm 190mm 190mm 20mm Margin A4 3 times 99mm 210mm 190mm 210mm 297 or 305mm Map fold Lg 840mm 8 times 105mm 210mm Step 2 Cross Fold 297mm 297mm 297mm 297mm 297mm 305mm 210mm 305m...

Страница 8: ...LED is on and the arrow key do not work for ejection procedure it means that all sensors are covered by paper It s necessary to uncover one of sensor to enable the ejection procedure Selection Key If...

Страница 9: ...ock is face down leading Use the extractable support during cross fold procedure to avoid a wrinkled cross folded copy Using the collection tray copies Baby Fold Front Folder tray The copies fan folde...

Страница 10: ...fold Before to perform the Automatic Eject Procedure try to pull back the paper manually from the bridge Automatic Eject Procedure Press the arrow key for 5 10 seconds to get out the copy the folding...

Страница 11: ...of 19 panels for unlimited fold capability Cross Folding maximum length 1680 mm 8 panels 15 C 32 C 60 F 90 F 3 35 85 RH3 Paper weight 75 80 90 gsm Only for P4 steady or flashing program it s possible...

Страница 12: ...e is 3mm Example 3times 9 297mm or 8 times 105mm 840mm 5 The folder often jams Paper curled or more than 90 gsm weight Wrong Fan folding Program Use paper not curled and 75 80 90 gsm weight Do not sel...

Отзывы: