Baby Fold Operator Manual  

11

 

Problem Solving 

 

 

 

N° SYMPTOM

 

CAUSE

 

SOLUTION

 

 

 

 

Folder does not switch on. 

 

-  Power source is off. 

-  Ensure that the power cable is connected  
-  Check the fuses on the folder power plug 

Folder first panel damaged 

 

-  Paper lead edge curled and 1

st

 panel 3- 5 mm 

longer than other panels 

-  Perform the adjustment procedure of fold program 

panel by removing 3-5  mm  (1A= -3/-5mm). 

The folder emits a sound when a copy is feed. 
 

-  The folder is still folding the previous copy 

 

-  The copy was not cover S3 introducing sensor 

-  Wait that the current folding process is over 

 

-  Check the folding program plot length too short if A4 

or A size select P4 

Copy package not correct 

-  Program P4 with steady or flash led require 

exact plot length 

-  Copy fold package tolerance is  ± 1mm 
-  20 or 25mm margin tolerance is ± 3mm  

-  Example  3times 9=297mm or 8 times 105mm=840mm 

The folder often jams 

-  Paper curled or more than  90 gsm weight 
-  Wrong Fan folding Program 

-  Use paper not curled and 75 – 80 – 90 gsm weight 
-  Do not select P3 flashing for fan folding 

6  

Folder at switch on, Motor runs immediately 

-  Sensor S0 is damaged or active 

-  Remove paper under sensor S0 , press reset and off and 

on then folder. If problem persist  open a service call . 

The arrow key do not eject paper jammed 
from folder 

-  All sensors are covered 

-  Remove paper from one of sensor and than do the 

manual ejection 

Folder beeps every 4 seconds and lit on red 
led as orange led 

-  Folder have reached number of fold limit, trial 

time or loan time expired 

-  Call service  

Folder folds cross fold panel 297mm,11”,12” 
instead of fan fold panel dimension 

-  Paper edge out of square or missed copy feed  

-  Sensor SO cover not at same time of sensor S1 

10 

Automatic Eject procedure failure 

-  Paper stuck between mobile roller and plate 

-  Pull out the paper from the folder entrance 

 

Содержание Baby Fold

Страница 1: ...GERA Baby Fold Operator Manual Revision December 2014...

Страница 2: ...TION 4 ENVIRONMENTAL COMPLIANCE 4 WARRANTY 4 GENERAL NOTE 5 FOLD PACKAGE DIMENSION 5 PAPER SPECIFICATION 5 FLOOR SPECIFICATION 5 FOLDER VERSION 5 FOLD PROGRAMS 6 CONTROL PANEL 7 FAN FOLDING PROCEDURE...

Страница 3: ...f you are not sure that your electrical supply meets the requirements please consult your local power company for advice WARNING This product must be connected to a protective grounded circuit This pr...

Страница 4: ...let if you are unable to insert the plug into it Never use a plug that lacks a grounded connection terminal to connect the product to an electrical outlet Always follow all warnings and instructions t...

Страница 5: ...operate this equipment Product Safety Certification This product is certified by following the Safety standards EN60950 Regulatory Information The CE mark applied to this product symbolizes GERA s de...

Страница 6: ...ds a poor quality and increases a folding jams All types of paper different from the common must not be folded Mylar or polyester film must not enter the folder as they can also cause jams and damage...

Страница 7: ...TRIC Step 1 Fan Fold 210mm 190mm 190mm 20mm Margin A4 3 times 99mm 210mm 190mm 210mm 297 or 305mm Map fold Lg 840mm 8 times 105mm 210mm Step 2 Cross Fold 297mm 297mm 297mm 297mm 297mm 305mm 210mm 305m...

Страница 8: ...LED is on and the arrow key do not work for ejection procedure it means that all sensors are covered by paper It s necessary to uncover one of sensor to enable the ejection procedure Selection Key If...

Страница 9: ...ock is face down leading Use the extractable support during cross fold procedure to avoid a wrinkled cross folded copy Using the collection tray copies Baby Fold Front Folder tray The copies fan folde...

Страница 10: ...fold Before to perform the Automatic Eject Procedure try to pull back the paper manually from the bridge Automatic Eject Procedure Press the arrow key for 5 10 seconds to get out the copy the folding...

Страница 11: ...of 19 panels for unlimited fold capability Cross Folding maximum length 1680 mm 8 panels 15 C 32 C 60 F 90 F 3 35 85 RH3 Paper weight 75 80 90 gsm Only for P4 steady or flashing program it s possible...

Страница 12: ...e is 3mm Example 3times 9 297mm or 8 times 105mm 840mm 5 The folder often jams Paper curled or more than 90 gsm weight Wrong Fan folding Program Use paper not curled and 75 80 90 gsm weight Do not sel...

Отзывы: