manualshive.com logo in svg
background image

  

GERA Baby Fold Operator Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision December 2014 

Содержание Baby Fold

Страница 1: ...GERA Baby Fold Operator Manual Revision December 2014...

Страница 2: ...TION 4 ENVIRONMENTAL COMPLIANCE 4 WARRANTY 4 GENERAL NOTE 5 FOLD PACKAGE DIMENSION 5 PAPER SPECIFICATION 5 FLOOR SPECIFICATION 5 FOLDER VERSION 5 FOLD PROGRAMS 6 CONTROL PANEL 7 FAN FOLDING PROCEDURE...

Страница 3: ...f you are not sure that your electrical supply meets the requirements please consult your local power company for advice WARNING This product must be connected to a protective grounded circuit This pr...

Страница 4: ...let if you are unable to insert the plug into it Never use a plug that lacks a grounded connection terminal to connect the product to an electrical outlet Always follow all warnings and instructions t...

Страница 5: ...operate this equipment Product Safety Certification This product is certified by following the Safety standards EN60950 Regulatory Information The CE mark applied to this product symbolizes GERA s de...

Страница 6: ...ds a poor quality and increases a folding jams All types of paper different from the common must not be folded Mylar or polyester film must not enter the folder as they can also cause jams and damage...

Страница 7: ...TRIC Step 1 Fan Fold 210mm 190mm 190mm 20mm Margin A4 3 times 99mm 210mm 190mm 210mm 297 or 305mm Map fold Lg 840mm 8 times 105mm 210mm Step 2 Cross Fold 297mm 297mm 297mm 297mm 297mm 305mm 210mm 305m...

Страница 8: ...LED is on and the arrow key do not work for ejection procedure it means that all sensors are covered by paper It s necessary to uncover one of sensor to enable the ejection procedure Selection Key If...

Страница 9: ...ock is face down leading Use the extractable support during cross fold procedure to avoid a wrinkled cross folded copy Using the collection tray copies Baby Fold Front Folder tray The copies fan folde...

Страница 10: ...fold Before to perform the Automatic Eject Procedure try to pull back the paper manually from the bridge Automatic Eject Procedure Press the arrow key for 5 10 seconds to get out the copy the folding...

Страница 11: ...of 19 panels for unlimited fold capability Cross Folding maximum length 1680 mm 8 panels 15 C 32 C 60 F 90 F 3 35 85 RH3 Paper weight 75 80 90 gsm Only for P4 steady or flashing program it s possible...

Страница 12: ...e is 3mm Example 3times 9 297mm or 8 times 105mm 840mm 5 The folder often jams Paper curled or more than 90 gsm weight Wrong Fan folding Program Use paper not curled and 75 80 90 gsm weight Do not sel...