GV-QR1352 / DES1352
16
1
1.7.1 Wiring
By the wiring, you can change the following default settings of beeper and LED reactions
upon access granted and denied.
With
RS-485
connection to the controller,
One beep when a card / QR code approaches
Another one beep with green LED upon access granted
Another two beeps with red LED upon access denied
With
Wiegand
connection to the controller,
One beep upon access granted
One beep upon access denied
For example, you can add LED flashing for
Wiegand
readers, green LED along with beep
upon access granted and red LED along with beep upon access denied, by wiring the two
LED cables to the controller’s outputs.
Wiring LED to GV-AS Controller
The diagram below shows the connection for wiring Green LED using GV-AS410 as an
example. For Red LED, wire the orange cable to another output.
Wire Color
Function
Black GND
Orange Red
LED
Purple Green
LED
Wiring Beeper to GV-AS Controller
The diagram below shows the connection for wiring the beeper using GV-AS410 as an
example.
Wire Color
Function
Black GND
Gray Beeper
GV-AS410 Controller
NC
COM
NO
NC
COM
NO
Beeper (Gray)
12V
D0
D1
GND
(Black)
(Green & White)
(Blue & White)
(Red)
GV-QR1352