7.2 Digital I/O Settings
Note the I/O function is only available for
Box Camera
and
Bullet Camera
.
The I/O terminal block of Box Camera and the I/O wires of Bullet Camera
provide the interface for one external alarm and sensor device. For details
on the I/O interface, see
2.7 I/O Terminal Block
or
4.2.1 Connecting to the
Data Cable.
7.2.1 Input Settings
To activate the sensor input, select
Enable
.
Figure 7-10
Normal State:
You can set the input state to trigger actions by
selecting
Open Circuit (N/O)
or
Grounded Circuit (N/C)
.
Latch Mode:
Enable this option to have a momentary output alarm.
Trigger digital output relay:
When this option is enabled, the output
will be triggered once the input is activated.
Record:
Enable this option to start recording when the input is
triggered.
Send Video to Center V2:
Enable this option to send the images to
Center V2 when the input is triggered.