Contractor:
P.O.:
Engineer:
Project Name:
Unit Tag:
The manufacturer works continually to improve its products. As a result, the design and speci
fi
cations of each product at the time of order may be changed without notice. Purchaser’s approval of this data set signi
fi
es that the equipment is acceptable under the provisions
of the job speci
fi
cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer’s opinion or commendation of its products. York and Af
fi
nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
SD2500AG 05/21
2
Page _____ of _____
Aston Series
1 - 6 Tons 60Hz
16
1
1-2
4
5-7
8
9
Model Type
16 –
Aston Advanced
Water-to-Air
Type
1 –
Vertical
2 –
Horizontal
Vintage
* –
Factory use Only
Unit Capacity (MBTUH)
026, 038, 049,
064, 072
Discharge Configuration
T
–
Top (Vertical)
B
–
Bottom (Vertical)
E
–
End (Horizontal)
S
–
Side (Horizontal)
Air Configuration
L
–
Left
R
–
Right
Voltage
1 – 208
-
230/60/1
Future Option
0 - Standard
Controls Option
D
–
Aurora Performance & Refrigeration Package
Air Coil Option
0 –
Standard, Uncoated
Filter Option
0 – 2"
MERV 11 Filter
Coax Option
C
–
Copper
N
–
CuproNickel
Blower Option
1 –
Variable Speed ECM Blower
4 –
5-Speed ECM
Hot Water Generation
0 –
No HWG, No IntelliStart
®
1 –
HWG with Factory Installed Pump, No IntelliStart
1
3 –
No HWG, IntelliStart
2
4 –
HWG with Factory Installed Pump, IntelliStart
1,2
Rev.:
04/30/2021
10
11
12
14
*
038
T
L
1
1
1
C
0
13
0
15
D
16
0
17
3
Notes:
1 –
HWG available on
026– 072
2 –
IntelliStart available on 026
– 072
10
1
1-2
4
5-7
8
9
Model Type
10 –
Aston Water-to-Air
Type
1 –
Vertical
2 –
Horizontal
Vintage
* –
Factory Use Only
Unit Capacity (MBTUH)
012, 018, 022, 026, 030, 036, 038,
042, 048, 049, 060, 064, 070, 072
Discharge Configuration
T
–
Top (Vertical)
B
–
Bottom (Vertical 022-072)
E
–
End (Horizontal)
S
–
Side (Horizontal)
Air Configuration
L
–
Left
R
–
Right
Voltage
1 – 208
-
230/60/1
Future Option
0 - Standard
Controls Option
A
–
Aurora
TM
Base Control (ABC)
Air Coil Option
0 –
Standard, Uncoated
Filter Option
0 – 2"
MERV 11 Filter
Coax Option
C
–
Copper
N
–
CuproNickel
Blower Option
0 –
PSC (012 Only)
1 –
Variable Speed ECM Blower (018-072)
4 –
5-Speed ECM (022-072)
Hot Water Generation
0 –
No HWG, No IntelliStart
®
1 –
HWG with Factory Installed Pump, No IntelliStart
1
3 –
No HWG, IntelliStart
2
4 –
HWG with Factory Installed Pump, IntelliStart
1,2
Rev.:
04/30/2021
10
11
12
14
*
038
T
L
1
1
1
C
0
13
0
15
A
16
0
17
3
Notes:
1 –
HWG available on 022
– 072
2 –
IntelliStart available on 022
– 072
Model Nomenclature - Aston
Model Nomenclature - Aston Advanced