Contractor:
P.O.:
Engineer:
Project Name:
Unit Tag:
The manufacturer works continually to improve its products. As a result, the design and speci
fi
cations of each product at the time of order may be changed without notice. Purchaser’s approval of this data set signi
fi
es that the equipment is acceptable under the provisions
of the job speci
fi
cation. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer’s opinion or commendation of its products. York and Af
fi
nity are registered
trademarks of Johnson Controls, Inc., and are used with permission.
Wiring Schematics cont.
Aurora Advanced with ECM and IntelliStart cont.
Brown
ECM
Blower
Motor
P12
P11
2
3
4
5
1
Green
16 1
12 15 10
PWM
C1
C2
R
G
33
CFM
To P2 on
Electric Heat
Board
Violet(42)
Blue(24)
Yellow(25)
Green/Yellow(28)
1
C
2
4
3
2
Orange
NOTE 9
NOTE 3
Current Transducer (CT)
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
K5 -
K6 -
CR3 -
CR4 -
F1 and F2 -
WCL -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW1 -
SW2 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Water Coil Limit Sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 5 position AXB
TEST MODE ABC Board
DIP package 8 position ABC Board
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
G
T
1
3
2
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4 -
Aux heat stage relays
HWL -
Hot water limit sensor
SC -
Start Contactor
Start Relay
SR -
CS -
Compressor Solenoid
Breaker
NOTE 4
P3 from unit’s control box
connects to P2
2
3
P9
5
4
1
L2
L1
L2
L1
G
G
Circuit 1
Circuit 2
NOTE 2
208-230/60/1
208-230/60/1
Green
Connects to variable
speed ECM motor only
P11
2
3
4
5
1
NOTE 6
With optional EA Series 20kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
Gray
Black
Yellow
Pink
Blue
2 - Use manufacturer’s part number 19P592-01 (jumper
bar assembly) when single source power is required.
3 – When Auxiliary Heat is installed the BLK/WHT
wire from CC-L1 to PB2-2 and the GRY/WHT wire
from CC-L2 to PB2-1 must be removed (located in
the heat pump control box).
1 - Use copper or aluminum conductors.
6 – Jumpers wires are Factory Installed, and are
required for auxiliary heat operation.
Black
Gray
Yellow
Pink
Yellow
Pink
Gray
EHC
EHC
Yellow
Blue
ER1
ER2
ER3
ER4
NO
NO
NO
NO
EA Series PCB
P2
C
1
2
3
4
P1
4
1
2
3
C
G
G
G
G
Pink
Black
Violet
Blue
Brown
Orange
HE1
TS1
HE2
TS2
HE3
TS3
HE4
TS4
Green
Gray
Black
Brown
Orange
To PB2
5 – Low voltage wiring CLASS 2.
4 - When installed, the Auxiliary Heat powers blower and controls.
L1
L2
Single Disconnect Power
208-230/60/1
Aux Elect Power
208-230/60/1
L1
L2
L1
L2
Unit Power
208-230/60/1
CSA installed units only
Local codes may require a single
source of power supply
Breaker box
furnished by
installer
Circuit Breakers
Notes
3 – When Auxiliary Heat is field installed the harness will then be connected to
the auxiliary heat unit. The auxiliary heat unit will then power the blower. Refer to
EAS/EAM/EAL Auxiliary Heat kit installation instructions.
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
9 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
5 – Brown blower power wire routed through Current Transducer two times.
6 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
7 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
4 – Low voltage wiring CLASS 2.
8 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
10 – Ground wire only on units with aluminum air coils.
SD2500AG 05/21
51
Page _____ of _____
Aston Series
1 - 6 Tons 60Hz