background image

 

 

 

 

© 2021GeoSLAM                                                                                                                                 ZEB

GO User Guide v1.0.7 

 

SAFETY 

 

2.1 

GENERAL SAFETY  

The  ZEB-GO  Portable  Mapping  System  should  only  be  used  by  trained  operators.  Always  follow  basic  safety  precautions  when 
operating the ZEB-GO Portable Mapping System to reduce the risk of personal injury and to prevent damage to the equipment.  Do 
not  operate  the  equipment  with  suspected  defects  or  obvious  mechanical  damage.  Please  refer  all  servicing  of  the  equipment  to 
qualified service personnel. Only use the components and accessories supplied with your system or other accessories recommended 
by GeoSLAM Ltd.  Before operating the system for the first time please read this guide in full. 

The equipment contains sensitive electrical and mechanical parts and thus requires appropriate handling.  Do not bend or pull the 
cables forcibly. Never push objects of any kind into the connectors or sockets. Keep the equipment out of the reach of children. Under 
no circumstances should any modifications be made to the ZEB-GO Portable Mapping System without prior written permission from 
GeoSLAM Ltd. 

 

2.2 

LASER SAFETY  

The ZEB-GO incorporates a Hokuyo UTM-30LX laser scanner.  The UTM-30LX-F is classified as a 
CLASS 1 Laser Product in accordance with IEC 60825-1: 2007 (2nd Edition) 

Safety of laser products. 

Equipment  classification  and  requirements. 

Class  1  Laser  Products  are  safe  under  reasonably 

foreseeable conditions of operation, including the use of optical instruments for intra-beam viewing. 

  

2.3 

ELECTROMAGNETIC COMPATABILITY  

The ZEB-GO Portable Mapping System meets or exceeds the following standards: 

EN61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Industrial Location Immunity 
- (immunity section only) 

EN61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Group 1, Class A equipment 
- (emissions section only) 

CFR 47 Code of Federal Regulations: Pt 15 Subpart B- Radio Frequency Devices - Class A Unintentional Radiators 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. 
These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  when  the  equipment  is  operated  in  a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the user guide, may cause harmful interference to radio communications. Operation of this equipment in a residential 
area may cause interference. 

2.4 

BATTERY SAFETY  

DO NOT attempt to dismantle the battery. 

DO NOT short circuit the battery. 

ONLY use the charger supplied with the system. 

Excess heat will degrade the battery rapidly. Always store the battery in a cool dry place.  DO NOT leave for long periods in the sun 
or in a hot vehicle. 

The battery is splash proof but not waterproof 

 do not immerse in water. 

2.5 

SYSTEM DISPOSAL  

When the ZEB-GO Portable Mapping System reaches the end of its life-cycle please dispose of the equipment in 
accordance with Directive 2002/96/EC on Waste Electrical and Electronic equipment (WEEE). 

 

GeoSLAM Ltd is prepared to take back the waste equipment and accessories free of charge at the manufacturing 
unit in Ruddington, UK for proper treatment with the objectives of the WEEE. 

 

 

2.6 

INSTALLATION  

The ZEB-GO can be used as a handheld device using the supplied removable handle or can be mounted to mobile platform using the 
supplied mounting plate (see Section 7.2).  

2.7 

FURTHER HELP AND INFORMATION  

In the event of a problem that cannot be resolved using the information supplied, please contact GeoSLAM.  You can also gain assistance 

through the support page on our website: https://geoslam.com/support/ 

For further assistance, contact the GeoSLAM Technical Support by telephone or email.  Our Customer Support personnel will discuss your 

situation, determine the cause of problem and provide the appropriate technical assistance. 

Contact GeoSLAM by any of the following methods: 

 

Phone: +44 (0) 1157 270740 (all countries) 

 

Phone: +1-833-444-7907 (US & Canada) 

 

Email: [email protected]

Содержание ZEB-GO

Страница 1: ...1 2021GeoSLAM ZEB GO User Guide v1 0 7 Copyright ZEB GO User Guide 2020 GeoSLAM Ltd All rights reserved ZEB GO User Guide...

Страница 2: ...de may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct t...

Страница 3: ...g the raw scan data 9 3 4 File naming 9 3 5 Shutting down 9 Usage Guidelines 11 4 1 The environment 11 4 2 Loop closure 11 4 3 Transitioning between environments 11 4 4 Walking speed 11 4 5 Minimum an...

Страница 4: ...aken with traditional terrestrial laser scanning methods 1 1 SPECIFICATION Maximum range Up to 30m in optimal conditions Typical max range 15 20m Points per scan line 1080 0 25o interval Field of view...

Страница 5: ...ZEB GO captures raw laser range measurement and inertial data This data must be processed using GeoSLAM s SLAM algorithm to convert the raw data into a 3D point cloud The data is processed using the...

Страница 6: ...ices Class A Unintentional Radiators This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to p...

Страница 7: ...te to the bottom of the handle using the screw and hex key provided Connect the ZEB GO main cable to the socket on the side of ZEB GO scanner head Use red dots to align correctly Connect the other end...

Страница 8: ...mode for 15 seconds the LED will switch to green Scanning mode Press the motor start stop button on the side of the scanner head to start the scanner rotation and commence the survey Step 4 When the...

Страница 9: ...capacity or the format is not recognised the AUX LED will flash red The raw data will remain on the internal memory of the data logger The following memory stick file formats are supported exFAT FAT16...

Страница 10: ...ing data is being logged Red flash green Warning low battery voltage Red flash x 1 Error scanner not detected Red flash x 2 Error IMU not detected Red flash x 3 Error neither scanner nor IMU detected...

Страница 11: ...the compounding of any error introduced causing measure position to drift It is good survey practise to close the loop by re surveying a known position so that the compounded error can be spread arou...

Страница 12: ...or short periods of time whilst the operator negotiates difficult access points e g tight squeezes in cave systems The scanning head can also be held in the hand and moved up and down to mimic the nor...

Страница 13: ...e Drop datasets here field on the user interface see Figure 5 1 The application will copy the dataset into a processing folder A processing progress bar is displayed as the data set being processed Th...

Страница 14: ...ing the battery store in a charged state Recharge after every 6 months Excess heat will degrade the battery rapidly Always store the battery in a cool dry place DO NOT leave for long periods in the su...

Страница 15: ...lect the Drive with the USB memory stick see Figure 7 2 and check the tick box against the task you want to perform In order to Download Specific Files enter the date of the required files YYYY MM DD...

Страница 16: ...16 2021GeoSLAM ZEB GO User Guide v1 0 7 7 2 APPENDIX 2 DIMENSIONAL DRAWINGS Dimensional drawings with optional mounting plate on rear face...

Страница 17: ...17 2021GeoSLAM ZEB GO User Guide v1 0 7 Dimensional drawings with optional mounting plate on bottom face...

Отзывы: