![Geosense IPI-H-1 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/geosense/ipi-h-1/ipi-h-1_instruction-manual_2215479006.webp)
6
V1.0 September 2017
The A axis is the primary axis and the B axis is the secondary axis. Uni
-
axial IPI
sensors only detect changes in the A axis.
After their installation, the vertical profile of the inclinometer casing is established
from the readings of individual IPI sensors. Changes to the verticality of a vertical or
inclined inclinometer casing (changes in the horizontal plane) are detected by the
sensor and the magnitude of the change is simply computed from the equation
‘
current reading
-
initial reading
’.
Horizontal IPI
’
s detect vertical movement of the
inclinometer casing.
(Continued from page 5)
1.3 The measurement of tilt