System components
-
extension rod version
Illustrated below are the typical components of a typical IPI installation
1
-
TOP HANGER
Used to suspend the complete IPI string. Placed
on the top of the 70mm inclinometer casing
INSTALLATION FORK
-
(not shown)
Used to support the IPI string during installation. It
fits into two slots on top of the IPI sensor and is
placed on top of the inclinometer casing
2
-
TOP STEEL WIRE BOND
A 3mm wire suspension rope used to position the
first sensor at the required depth and is connected
to the top collar hanger and the IPI top fly lead
assembly (G86
-
502). Available either as pre
-
assembled lengths (1, 2, 3, 4m) or supplied as site
adjustable
3
-
IPI TOP FLY LEAD ASSEMBLY
A universal component which acts as top
suspension and cable connector. Fitted as
standard with 4.5m of digital BUS cable for
connection to a readout or data logger. Other
cable lengths available on request.
4
-
IN
-
PLACE INCLINOMETER PROBE (IPI)
Instrument fitted with one (Uniaxial) or two
(Biaxial) MEMS sensors. It is mounted within a
watertight stainless steel tube fitted with two wheel
sets that run in the internal grooves of inclinometer
casing. One set has a fixed wheel and the other is
sprung loaded. The output from the sensors is
digital RS
-
485 BUS so that several IPIs can be
connected together on one single cable
5
-
EXTENSION RODS
Used to connect each IPI sensor together to
create a tilt profile. Specially designed quick
connecting fittings on each end, together with an
integral internal signal cable. Available in 0.5, 1,
1.5, 2, 3m lengths. (Special lengths are available
on request)
6
-
BOTTOM WHEEL/TERMINATION
ASSEMBLY
Fitted with a rigid joint, the bottom wheel assembly
acts as the base reference from which all other
readings are taken. It is fitted with an integral end
termination resistor which is required at the end of
the RS
-
485 string
7
-
WI
-
SOS 480 WIRELESS DIGITAL NODE
Up to 30 IPI sensors can be attached to each
node
8
-
GEOLOGGER G8 PLUS
Automatic data acquisition system
1
8
7
5
4
4
2
3
6
5