
FIGURES
F
IGURE
1
-
M
ODEL
4500S
V
IBRATING
W
IRE
P
IEZOMETER
.............................................................. 1
F
IGURE
2
-
4500C
S
ATURATION
....................................................................................................... 4
F
IGURE
3
-
T
YPICAL
L
EVEL
M
ONITORING
I
NSTALLATION
................................................................ 8
F
IGURE
4
-
T
YPICAL
B
OREHOLE
I
NSTALLATIONS
........................................................................... 10
F
IGURE
5
-
H
IGH
A
IR
E
NTRY
F
ILTER
.............................................................................................. 12
F
IGURE
6
-
L
OW
A
IR
E
NTRY
F
ILTERS
ONLY ................................................................................. 13
F
IGURE
7
-
T
YPICAL
S
OFT
S
OILS
I
NSTALLATION
............................................................................ 14
F
IGURE
8
-
T
YPICAL
M
ULTI
-P
IEZOMETER
I
NSTALLATION
.............................................................. 16
F
IGURE
9
-
R
ECOMMENDED
L
IGHTNING
P
ROTECTION
S
CHEME
...................................................... 17
F
IGURE
10
-
L
EMO
C
ONNECTOR TO
GK-404 .................................................................................. 18
F
IGURE
11
-
L
IVE
R
EADINGS
–
R
AW
R
EADINGS
............................................................................. 19
F
IGURE
12
-
T
YPICAL
C
ALIBRATION
R
EPORT
................................................................................. 23
F
IGURE
13
-
4500AR ..................................................................................................................... 33
TABLES
T
ABLE
1
-
C
EMENT
/B
ENTONITE
/W
ATER RATIOS
............................................................................ 11
T
ABLE
2
-
E
NGINEERING
U
NITS
M
ULTIPLICATION
F
ACTORS
.......................................................... 23
T
ABLE
3
-
S
AMPLE
R
ESISTANCE
..................................................................................................... 27
T
ABLE
4
-
R
ESISTANCE
W
ORK
S
HEET
............................................................................................ 27
T
ABLE
5
-
V
IBRATING
W
IRE
P
IEZOMETER
S
PECIFICATIONS
........................................................... 29
T
ABLE
6
-
S
TANDARD
P
IEZOMETER
W
IRING
.................................................................................. 29
T
ABLE
7
-
T
HERMISTOR
R
ESISTANCE VERSUS
T
EMPERATURE
........................................................ 30
T
ABLE
8-
T
HERMISTOR
R
ESISTANCE VERSUS
T
EMPERATURE FOR
H
IGH
T
EMPERATURE
M
ODELS
. 31
EQUATIONS
E
QUATION
1
-
D
IGITS
C
ALCULATION
............................................................................................. 22
E
QUATION
2
-
C
ONVERT
D
IGITS TO
P
RESSURE
............................................................................... 22
E
QUATION
3
-
T
EMPERATURE
C
ORRECTION
................................................................................... 24
E
QUATION
4
-
B
AROMETRIC
C
ORRECTION
..................................................................................... 25
E
QUATION
5
-
C
ORRECTED
P
RESSURE
C
ALCULATION
.................................................................... 25
E
QUATION
6
-
R
ESISTANCE TO
T
EMPERATURE
............................................................................... 30
E
QUATION
7
-
H
IGH
T
EMPERATURE
R
ESISTANCE TO
T
EMPERATURE
............................................. 31
Содержание 4500AL
Страница 2: ......