background image

Genvex World Wide:

www.genvex.dk

Copenhagen

Billund

Hamburg

Intelligent ventilation system from Genvex

As  ventilation  specialists,  we  offer  a  product  range  that 

covers all aspects of modern ventilation equipment, from 

passive  ventilation  units  with  highly  effective  counter 

current  exchangers  to  units  with  integrated  heat  pumps 

that are extremely power efficient for heating or cooling. 

We  can  also  provide  units  for  ceiling  mounting  for 

installation in existing office buildings, high-rise buildings 
and industrial buildings.

Denmark

Genvex A/S

DK - 6100 Haderslev

Tel.: +45 73 53 27 00

Fax: +45 73 53 27 07 

E-Mail: [email protected] 

Norwegian

Varmeteknikk Norge

N - 2240 Magnor

Tel.: +47 62 83 21 50

Fax: +47 62 83 21 59 

E-Mail: [email protected]

Germany

Novelan GmbH

D-95359 Kasendorf

Tel.: +49 (0) 92 28 / 99 60 7-0

Fax: +49 (0) 92 28 / 99 60 7-189

E-Mail: [email protected] 

Belgium

 

Artiklima bvba

B - 9220 Hamme

Tel.: +32 (0) 52 41 25 41

Fax: +32 (0) 52 41 29 66 

E-Mail: [email protected] 

Great Britain 

Total Home Environment Ltd

GB- Moreton in Marsh, GL 56 0JQ

Tel.: +44 (0) 845 260 0123

Fax: +44 (0) 1608 652490 

E-Mail: [email protected] 

Ireland / N.I.

ECO Systems Ireland Ltd

Co. Antrim BT54 6PH

Tel.: (UK 028) (ROI 048) +44 2076 8708 

Fax: (UK 028) (ROI 048) +44 2076 9781 

E-Mail: [email protected] 

Schwitzerland

Wesco AG

CH-5430 Wettingen

Tel.: +41 (0) 56 438 11 11

Fax: +41 (0) 56 438 12 10 

E-Mail: [email protected] 

Austria

J.Pichler Lufttechnik GmbH

A-9021 Klagenfurt

Tel.: +43 (0) 463 / 3 27 69

Fax: +43 (0) 463 / 3 75 48

E-Mail: [email protected]

Slovenia

  

Pichler & CO d.o.o.

2000 Maribor

Tel.: +386/ (0) 2/460 13 50

Fax: +386/ (0) 2/460 13 55

E-Mail: [email protected]

Croatia

Pichler & CO d.o.o.

10000 Zagreb

Tel.: + 385/ (0) 1/ 65 45 407 

Fax: + 385/ (0) 1/ 65 45 409

E-Mail: [email protected]

Portugal

Iberterm

PT-4475-493 Nogueira Maia

Tel: +351 229 065 123/4

Fax: +351 229 065 125

E-Mail: [email protected]

Web: www.iberterm.com 

Published by Genvex A/S, Sverigesvej 6, DK-6100 Haderslev

Presented by:

Содержание GE Premium 1/1L

Страница 1: ...Version V1 04 0310 GB Installations Manual Active Ventilation Heat pump GES Premium 1 1L GE Premium 1 1L GE Premium 2 GE Premium 3...

Страница 2: ...ts in cold loft spaces 6 Insulation of ducts in heated spaces 7 Electrical installation 7 Commissioning of the unit 8 Maintenance of the unit 8 Fault finding 10 Electrical diagram GE Premium serie 11...

Страница 3: ...ing when the IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT temperature drops below 2C 7 Air flow adjustments must be made on both the supply and e...

Страница 4: ...ons from the unit cannot be transferred through ceiling and walls and so that the condensate drain with the necessary water trap can be led to an inside drain without danger of freezing in cold weathe...

Страница 5: ...commended that the duct system is made of spiral ducting with rubber ring seal fittings in order to provide a tight and durable duct system To achieve a satisfactory low sound level from the unit sile...

Страница 6: ...ducts in cold loft spaces In order to high recovery rate of the unit it is necessary to insulate the ducts correctly Supply and extract ducts Supply and extract air duct To minimize heat losses from...

Страница 7: ...easuring equipment If you wish to start up the unit before adjustment do as follows Before starting up the unit 1 Make sure that the Genvex unit is correctly mounted and that all ducts are insulated a...

Страница 8: ...el flashes the filters must be changed cleaned Stop the unit on the switch on the unit or the electrical panel Open the front cover and take out the filter When the filter has been changed or cleaned...

Страница 9: ...heck the two fan wheels for dirt If they are dirty they may be cleaned with a brush bottle washer etc Supply and extract valves Clean the valves by wiping them with a dry cloth Make sure the valve doe...

Страница 10: ...living rooms Fault Defect fan Blocked filter Fresh air grill is blocked by dirt and leaves in the autumn or snow and ice in the winter Fuse on control circuit board has blown No extract air from wet r...

Страница 11: ...Costumer Yours ref Construct KS Order no Our ref Rev Type GES Premium 1 and 2 EC Date 23 02 20 Page 1 of 1 Serial...

Страница 12: ...Premium range Evaporator cooling coil High pressure switch Condenser heating coil MA4 Compressor Control panel MA7 HP Exhaust Air Supply Air T4 T5 T3 T6 T1 T7 T2 Extract Air Fresh Air Counter current...

Страница 13: ...13 Notes...

Страница 14: ...14 Notes...

Страница 15: ...15 Notes...

Страница 16: ...m Artiklima bvba B 9220 Hamme Tel 32 0 52 41 25 41 Fax 32 0 52 41 29 66 E Mail info artiklima be Great Britain Total Home Environment Ltd GB Moreton in Marsh GL 56 0JQ Tel 44 0 845 260 0123 Fax 44 0 1...

Отзывы: