6
Installation
3 m
1 m
3 m
Friskluft
Incomming Air
Frischluft
Afkast
Exhaust Air
Fortluft
Udsugning
Extract Air
Abluft
Indblæsning
Supply Air
Zuluft
Afløb
Duct connection
All duct connections display a yellow sticker indicating the
type of ventilation channel to be connected.
Connect the supply air:
Duct system from the unit to the supply outlet in the living
room.
Connect the extract air:
Duct system from wet rooms to the unit.
Connect the fresh air:
Duct system from fresh air roof cowls/external grills from
the ground collector to the unit.
Connect the exhaust air:
Duct system from unit to the escaping roof cowls/external
grills.
Duct system
It is recommended that the duct system is executed in
spiral ducting connected with rubber ring seal fittings in
order to provide a leak-free and durable duct system.
To achieve a satisfactory low sound level from the unit,
sound locks must always be fitted to the supply and extract
duct system between the unit and the first supply and
extract fittings.
It is recommended that air speeds in the ducts are
dimensioned at sufficiently low level to prevent noise from
the supply and extract fittings.
When positioning fresh air and extract roof cowls/grills,
make sure the two air flows do not intercept, causing
escaping air to be drawn in again.
It is recommended that grills are placed on the north or
east side of the house to provide optimum comfort.
100 mm
Siphon
To internal drain
Extract Air
Fresh Air
Supply Air
Exhaust Air
Lack of water in siphon = water damage
1%