background image

Genvex World Wide:

www.genvex.dk

Copenhagen

Billund

Hamburg

Intelligent ventilation system from Genvex

As  ventilation  specialists,  we  offer  a  product  range  that 

covers all aspects of modern ventilation equipment, from 

passive  ventilation  units  with  highly  effective  counter 

current  exchangers  to  units  with  integrated  heat  pumps 

that are extremely power efficient for heating or cooling. 

We  can  also  provide  units  for  ceiling  mounting  for 

installation in existing office buildings, high-rise buildings 
and industrial buildings.

Denmark

Genvex A/S

DK - 6100 Haderslev

Tel.: +45 73 53 27 00

Fax: +45 73 53 27 07 

E-Mail: [email protected] 

Norwegian

Varmeteknikk Norge

N - 2240 Magnor

Tel.: +47 62 83 21 50

Fax: +47 62 83 21 59 

E-Mail: [email protected]

Germany

Novelan GmbH

D-95359 Kasendorf

Tel.: +49 (0) 92 28 / 99 60 7-0

Fax: +49 (0) 92 28 / 99 60 7-189 

E-Mail: [email protected] 

Belgium

 

Artiklima bvba

B - 9220 Hamme

Tel.: +32 (0) 52 41 25 41

Fax: +32 (0) 52 41 29 66 

E-Mail: [email protected] 

Great Britain 

Total Home Environment Ltd

GB- Moreton in Marsh, GL 56 0JQ

Tel.: +44 (0) 845 260 0123

Fax: +44 (0) 1608 652490 

E-Mail: [email protected] 

Ireland / N.I.

ECO Systems Ireland Ltd

Co. Antrim BT54 6PH

Tel.: (UK 028) (ROI 048) +44 2076 8708 

Fax: (UK 028) (ROI 048) +44 2076 9781 

E-Mail: [email protected] 

Schwitzerland

Wesco AG

CH-5430 Wettingen

Tel.: +41 (0) 56 438 11 11

Fax: +41 (0) 56 438 12 10 

E-Mail: [email protected] 

Austria

J.Pichler Lufttechnik GmbH 

 

    

A-9021 Klagenfurt

Tel.: +43 (0) 463 / 3 27 69

Fax: +43 (0) 463 / 3 75 48

E-Mail: [email protected]

Slovenia

  

Pichler & CO d.o.o.

2000 Maribor

Tel.: +386/ (0) 2/460 13 50

Fax: +386/ (0) 2/460 13 55

E-Mail: [email protected]

Croatia

Pichler & CO d.o.o.

10000 Zagreb

Tel.: + 385/ (0) 1/ 65 45 407 

Fax: + 385/ (0) 1/ 65 45 409

E-Mail: [email protected]

Portugal

Iberterm

PT-4475-493 Nogueira Maia

Tel: +351 229 065 123/4

Fax: +351 229 065 125

E-Mail: [email protected]

Web: www.iberterm.com 

Published by Genvex A/S, Sverigesvej 6, DK-6100 Haderslev

Presented by:

Содержание GE ENERGY 1

Страница 1: ...Version 1 02 0110 GB Installations Manual Passive Ventilation Counter Current Heat Exchanger GE Energy 1 GE Energy 2 GE Energy 3...

Страница 2: ...on of ducts in cold loft spaces 7 Insulation of ducts in heated spaces 8 Reheating of supply air 8 Electrical installation 9 Inspection and initial adjustment of appliance 9 Optimum initial adjustment...

Страница 3: ...occur it is necessary to install a thermostat and electrical heater to prevent freezing when the temperature drops below 2C 7 Airflow adjustments must be made on both supply and exhaust sides for a no...

Страница 4: ...d rear panels may be removed the back panel mounted on the front and the unit rotated 180 This will cause the supply to exchange places with the escaping and the fresh air with the extract with the co...

Страница 5: ...to an internal drain without danger of freezing in cold weather as a unit may produce up to 8 10 litres of condensate per day To allow access for service and maintenance there must be a clear space of...

Страница 6: ...escaping roof cowls external grills Duct system It is recommended that the duct system is executed in spiral ducting connected with rubber ring seal fittings in order to provide a leak free and durabl...

Страница 7: ...sure that the water in it does not freeze If installation problems make it impossible to secure the condensate drain pipe from freezing by insulation it will be necessary to mount a thermostat control...

Страница 8: ...pply it to the supply air the supply air will be about 1 4 C colder than the room temperature in the dwelling for the whole winter season If this lower supply temperature is insupportable during cold...

Страница 9: ...ck that hatches can be opened so that service and maintenance on the unit can be carried out 3 Check that filters are clean may be dirty from installation work 4 Check that the condensate drain is cor...

Страница 10: ...d by shaking it and by removing the worst dirt switch on the unit and press the enter button on the control panel for 10 15 seconds until the Genvex logo starts flashing again and the equipment is bac...

Страница 11: ...ery year If it is dirty remove it and wash in warm soapy water and then rinse possibly in the bathroom using the shower head Fans Every year check the two fan wheels for dirt If they are dirty they ma...

Страница 12: ...oms Error Defective fan Blocked bag filter Fresh air grill blocked by dirt and leaves in the autumn or snow and ice in the winter Fuse on control circuit board has blown No power No extract air from w...

Страница 13: ...Yell Green Yell Green Blue Blue Yellow Yellow L N Wire no 5 Is not used No 3 White Nr 1 Black Nr 2 Red No 1 Black Nr 3 White No 2 Red Hy Set T1 90 C manu T1 90 C manu N PE L L PE N Optima 250 Control...

Страница 14: ...vex Hygrostat Potentialfree Contact Must be used Mains U 1x230V 50Hz 13 A 230V Controlrelay for Electrial Reheater L1 N Sensor Heatrelay Sensor defrost Optima 100 RJ 45 Hy Set T1 M1 Supply M2 Exhaust...

Страница 15: ...15 Installation EU Declaration of conformity...

Страница 16: ...m Artiklima bvba B 9220 Hamme Tel 32 0 52 41 25 41 Fax 32 0 52 41 29 66 E Mail info artiklima be Great Britain Total Home Environment Ltd GB Moreton in Marsh GL 56 0JQ Tel 44 0 845 260 0123 Fax 44 0 1...

Отзывы: