background image

Optima 310

Hours

Minutes

Le-
vel

Red. T2

  1)

  2)

  3)

  4)

  5)

  6)

  7)

  8)

  9)

10)

Monday

1.4 Week program scheme

Hours

Minutes

Le-
vel

Red. T2

  1)

  2)

  3)

  4)

  5)

  6)

  7)

  8)

  9)

10)

Tuesday

Hours

Minutes

Le-
vel

Red. T2

  1)

  2)

  3)

  4)

  5)

  6)

  7)

  8)

  9)

10)

Wednesday

Hours

Minutes

Le-
vel

Red. T2

  1)

  2)

  3)

  4)

  5)

  6)

  7)

  8)

  9)

10)

Thursday

Hours

Minutes

Le-
vel

Red. T2

  1)

  2)

  3)

  4)

  5)

  6)

  7)

  8)

  9)

10)

Friday

Hours

Minutes

Le-
vel

Red. T2

  1)

  2)

  3)

  4)

  5)

  6)

  7)

  8)

  9)

10)

Saturday

Hours

Minutes

Le-
vel

Red. T2

  1)

  2)

  3)

  4)

  5)

  6)

  7)

  8)

  9)

10)

Sunday

                       1.5 Defrost program

Before coil °C

Coil °C

15

-5

14

-5

13

-5

12

-6

11

-6

10

-7

9

-7

8

-8

7

-8

6

-9

5

-10

4

-10

3

-11

2

-12

1

-12

0

-13

-1

-14

-2

-14

-3

-15

-4

-15

Red. T2 = Reduced Room temperature

Содержание Combi 185

Страница 1: ...Version 3 04 0208 GB User Manual Combi 185 L LS S Optima 310 Heat Pump and Domestic Hot Water...

Страница 2: ...ry default scheme 10 2 Function 2 1 Controller Optima 310 11 2 2 Extra capacity 11 2 3 Operation safety 11 2 4 Warnings 11 3 Maintaining 3 1 Connecting to computer 12 3 2 Servicing 12 3 3 Water circui...

Страница 3: ...when the display shows 1 T1 Supply air T2 Room T3 Fresh air T4 Exhaust air T5 Before coil cooling coil T6 Coil cooling T7 D water top T8 D water bottom T9 Solar collector R1 Compressor R3 Air heating...

Страница 4: ...tank while the heat pump continues heating up the lower part to the operating temperature adjusted in menu point 5 8 R8 function This relay may be used as follows If the set point is 0 a circulation p...

Страница 5: ...w suppl It is recommended that the supply air volume is adjusted to 20 lower than the set value in menu point 22 14 Filter change The control system contains an integral timer which counts the time fo...

Страница 6: ...the relevant number of minutes 31 36 When the marker is pointing to menus between 18 and 23 the display heading changes to show actual changing point according to the following format Changepoint Wee...

Страница 7: ...ly from the outside 38 Default values Please notice Before resetting the values please ensure that the actual set points are noted in the scheme page 43 Here is an option for re adjusting the set poin...

Страница 8: ...8 Optima 310 53 Danish Select language 54 English Select language 55 German Select language 56 Polish Select language Danish 54 English 55 German 56 Polish Set point Operations menu Exit OK 5...

Страница 9: ...esday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Thursday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Friday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Saturday Hours Minutes Le vel R...

Страница 10: ...Arrow Up or Arrow Down This will change the clock hour by 1 hour in the desired direction Contrast adjustment Contrast of the display can be changed by pressing the Info button while the program info...

Страница 11: ...il has reached a temperature of app 5 C Then the magnetic valve closes again and the supply air fan and electric heating coil restart operation 2 2 Extra capacity Electric element If the hot water nee...

Страница 12: ...n unbalance and thereby a higher noise level and abrasion of the fans Supply and extract valves Clean the valves by wiping with a dry cloth Make sure the valve does not rotate causing a change in the...

Страница 13: ...t to check that the anode is intact at all times This should be done by inspecting the anode every 2 years and replacing it if it is corroded and measures only 6 10 mm in diameter To inspect the anode...

Страница 14: ...e heating element dismantled The reset button can now be pressed Please notice Be careful not to damage or tear the cables to the control 4 3 Heat pump will not operate Unit has stopped Please control...

Страница 15: ...15 Optima 310...

Страница 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...

Отзывы: