background image

4

 

Optima 310

By pressing “OK”, the control system reverts to the main 
menu and the text changes to English. Now all text in 
the display appear in English. If, instead, the set 
point is adjusted to “2”, all text in the display will 
be shown in German.
When the desired language has been selected, enter the 
main menu once again and change to the next operating 
point by pressing “Arrow down”.

If you wish to flick through the pages of the operating 

menu, you may press “Enter” to change the whole page to 
the next set of menu points.
If you wish to return to the previous operating point, 
you may press “Arrow up”.
If you wish to leave the operating menu, press “Exit”.
The operating menu will automatically shut down and 
return to the main menu if no button has been touched for 
app. 60 seconds, while in the operating menu.

1.3 Operating menu

1: Language

There is a choice of three languages
Set point 0 = Danish, 1 = English, 2 = German, 

2: Room temperature

The desired room temperature may be set between
10 - 30°C.
(The room sensor is installed the control panel).

3: Not in use

4: Not in use

5: Opr thermostat

The desired domestic water temperature may be set 
between 0 - 55°C, and will be heated by the heat pump. 

6: El. heater ON (domestic hot water)

By setting the set point to 1, the electric heating 
element will switch on whenever needed. If the set 
point is adjusted to 0, the electric heating element 
will not switch on, even if there is a need. At 
external temperatures below 0°C, it is an advantage 

>>Language

2  Room temperature

3  Not in use

4  Not in use

Set point  

  

Operations menu

Exit

OK

<

>

0

to use the electric heating element to supplement the 
domestic water heating, as this leaves more heat from the 
heat pump to be used for room heating

7: El. Heater (domestic hot water)

The desired domestic water temperature may be set 
between 0 - 65°C. The electric element only heats 
up the upper half of the tank, while the heat pump 
continues heating up the lower part to the operating 
temperature adjusted in menu point 5.

8: R8 function

This relay may be used as follows: If the set point is 
0, a circulation pump for the solar collector, may be 
connected. The control is of this device is according 
to point 20. If the set point is 1, a circulation pump 
for a water  after heating coil, may be connected. The 
pump will only switch on if there is a need for heating. 
If the set point is 2, you may connect supply and 
exhaust air dampers, which opens and closes, when the 
unit starts og stops.

9: Constant ON

If other heating systems of the house are not connected 

with the heat pump unit, or if there is a fire place, it may 

occur that the other heating systems, may stop the 
operation of the heat pump. Units without heat exchanger 
will blow external air directly into the house. By adjusting 
the set point to 1, the room sensor will be deactivated 
and the heat pump will be in constant use and blow in 
warm air when the external temperature is below the 
set minimum temperature in point 10. If the set point 
is adjusted to 0, the room sensor will regulate the heat 
pump regardless of the outside temperature.

10: Constant

If constant ON is activated, this ambient air 
temperature setting dictates the unit to change to 
constant operation if the actual ambient temperature 
is lower.
The set point may be set between 0° - 10° C.

11: Reduce ON

At very low ambient temperatures, it may be an 
advantage to reduce the supply air volume in order 
to improve the operating conditions of the heat pump 
and simultaneously achieve a higher supply of air 
temperature. By adjusting the set point to 1, the supply 
air volume will be reduced when the external temperature 
falls below the set temperature. If the set point is adjusted 
to 0, there will be no reduction of supply air volume 
regardless of the outside temperature. 

>>Opr thermostat

6  El. heater ON

7  El. heater

8  R6 function

Set point  

  

Operations menu

Exit

OK

<

>

0.0

>>Constant ON  

10Constant

11Cooling ON

12Cooling  

  

Set point

Operations menu

Exit

OK

<

>

0

Содержание Combi 185

Страница 1: ...Version 3 04 0208 GB User Manual Combi 185 L LS S Optima 310 Heat Pump and Domestic Hot Water...

Страница 2: ...ry default scheme 10 2 Function 2 1 Controller Optima 310 11 2 2 Extra capacity 11 2 3 Operation safety 11 2 4 Warnings 11 3 Maintaining 3 1 Connecting to computer 12 3 2 Servicing 12 3 3 Water circui...

Страница 3: ...when the display shows 1 T1 Supply air T2 Room T3 Fresh air T4 Exhaust air T5 Before coil cooling coil T6 Coil cooling T7 D water top T8 D water bottom T9 Solar collector R1 Compressor R3 Air heating...

Страница 4: ...tank while the heat pump continues heating up the lower part to the operating temperature adjusted in menu point 5 8 R8 function This relay may be used as follows If the set point is 0 a circulation p...

Страница 5: ...w suppl It is recommended that the supply air volume is adjusted to 20 lower than the set value in menu point 22 14 Filter change The control system contains an integral timer which counts the time fo...

Страница 6: ...the relevant number of minutes 31 36 When the marker is pointing to menus between 18 and 23 the display heading changes to show actual changing point according to the following format Changepoint Wee...

Страница 7: ...ly from the outside 38 Default values Please notice Before resetting the values please ensure that the actual set points are noted in the scheme page 43 Here is an option for re adjusting the set poin...

Страница 8: ...8 Optima 310 53 Danish Select language 54 English Select language 55 German Select language 56 Polish Select language Danish 54 English 55 German 56 Polish Set point Operations menu Exit OK 5...

Страница 9: ...esday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Thursday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Friday Hours Minutes Le vel Red T2 1 2 3 4 5 6 7 8 9 10 Saturday Hours Minutes Le vel R...

Страница 10: ...Arrow Up or Arrow Down This will change the clock hour by 1 hour in the desired direction Contrast adjustment Contrast of the display can be changed by pressing the Info button while the program info...

Страница 11: ...il has reached a temperature of app 5 C Then the magnetic valve closes again and the supply air fan and electric heating coil restart operation 2 2 Extra capacity Electric element If the hot water nee...

Страница 12: ...n unbalance and thereby a higher noise level and abrasion of the fans Supply and extract valves Clean the valves by wiping with a dry cloth Make sure the valve does not rotate causing a change in the...

Страница 13: ...t to check that the anode is intact at all times This should be done by inspecting the anode every 2 years and replacing it if it is corroded and measures only 6 10 mm in diameter To inspect the anode...

Страница 14: ...e heating element dismantled The reset button can now be pressed Please notice Be careful not to damage or tear the cables to the control 4 3 Heat pump will not operate Unit has stopped Please control...

Страница 15: ...15 Optima 310...

Страница 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...