24VDC CLEAR Lens Indoor Strobe Current Ratings

GEC24 and 

GES24 Series

Available Candela

GEC3-24 and 

GES3-24 Series 

Available Candela

Strobe

Candela

Regulated 24VDC

Max. Operating 

Current(mA)

Regulated 24VFWR 

Max. Operating 

Current (mA)

1

24VDC 

Nominal Operating

Current (mA) 

w

15

42

77

30

w

15/75

67

113

N/A

w

30

58

102

42

w

60

97

161

66

w

75

116

225

80

w

110

161

256

103

w

177

213

341

N/A

WGEC24, WGES24, WGECA24, WGESA24, WGECB24, WGESB24, WGECG24, WGESG24, WGECR24, WGESR24 PRODUCT INFORMATION

Models

Color Lens

WGECA24, WGESA24

Amber

WGECB24, WGESB24

Blue

WGECG24, WGESG24

Green

WGECR24, WGESR24

Red

NOTICE:

DC VOLTAGE RANGE LIMITS: 16-33V.  FWR

VOLTAGE RANGE LIMITS: 16-33V.  THIS PRODUCT WAS

ONLY TESTED TO THE STATED VOLTAGE RANGE(S); DO

NOT APPLY 80% AND 110% OF THIS RANGE FOR 

SYSTEM OPERATION.
1 When using products manufactured after 7-1-10, these 

values are to be used when calculating current draws.
N/A: 24VDC nominal operating current data not available

NOTICE:

DC VOLTAGE RANGE LIMITS: 16-33V.  FWR VOLTAGE RANGE LIMITS: 16-33V.  THIS PRODUCT WAS ONLY

TESTED TO THE STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM

OPERATION.
1 When using products manufactured after 7-1-10, these values are to be used when calculating current draws.

24VDC CLEAR & AMBER Lens Outdoor 

Strobe Current Ratings

Use with WGEC24, WGES24, 

WGECA24, WGESA24 Products

Candela

Regulated 24VDC 

Max. Operating 

Current (mA)

Regulated 24VFWR

Max. Operating 

Current (mA)

1

75

170

263

24VDC BLUE, GREEN & RED Lens Outdoor 

Strobe Current Ratings

Use with WGECB24, WGESB24, WGECG24,

WGESG24, WGECR24, WGESR24 Products

Candela

Regulated 24VDC 

Max. Operating 

Current (mA)

Regulated 24VFWR

Max. Operating 

Current (mA)

1

75

164

278

AMBER Lens Indoor Strobe Current Ratings

Use with GECA24 and GESA24 Products

Candela

Regulated 24VDC 

Max. Operating 

Current (mA)

Regulated 24VFWR

Max. Operating 

Current (mA)

1

15

47

82

30

64

112

60

113

178

75

145

213

110

178

259

GECA24, GESA24, GECB24, GESB24, GECG24, GESG24, GECR24, GESR24 PRODUCT INFORMATION

BLUE, GREEN & RED Lens Indoor 

Strobe Current Ratings

Use with GECB24, GESB24, GECG24, 

GESG24, GECR24, GESR24 Products

Candela

Regulated 24VDC 

Max. Operating 

Current (mA)

Regulated 24VFWR

Max. Operating 

Current (mA)

1

15

105

164

30

130

196

60

203

325

75

243

355

110

310

491

Models

Color Lens

GECA24, GESA24

Amber

GECB24, GESB24

Blue

GECG24, GESG24

Green

GECR24, GESR24

Red

NOTICE

: DC VOLTAGE RANGE LIMITS: 16-33V.  FWR VOLTAGE RANGE LIMITS: 16-33V.  THIS PRODUCT WAS ONLY TESTED TO THE

STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM OPERATION.

1

When using products manufactured after 7-1-10, these values are to be used when calculating current draws.

Horn Decibel Levels:

Reverberant Room

Horn Current Ratings Over 

Input Voltage Range of 16-33V

24VDC Nominal Horn 

Current Ratings

Horn Mode

Minimum SPL

at 10Ft. Per

ANSI/UL 464

(HIGH)

Minimum SPL

at 10Ft. Per

ANSI/UL 464

(LOW)

Regulated 24VDC

Max. Operating

Current (mA)

HIGH Setting

Regulated 24VFWR

Max. Operating

Current (mA) 

HIGH Setting

24VDC Operating

Current (mA) 

HIGH Setting

24VFWR Operating

Current (mA)

HIGH Setting

Temp 3 2400Hz

78 dBA

71* dBA

28

48

10.7

26.8

Temp 3 Mechanical

76 dBA

70* dBA

25

44

9.7

24.5

Temp 3 Chime

70* dBA

66* dBA

15

30

8.6

20.6

Continuous 2400Hz

81 dBA

74* dBA

28

48

20.4

43.7

Continuous Mechanical

80 dBA

72* dBA

25

44

17.0

39.3

Continuous Chime

70* dBA

66* dBA

15

30

9.6

23.0

Whoop

82 dBA

69* dBA

56

62

45.4

60.2

HORN DECIBEL AND CURRENT RATINGS PRODUCT INFORMATION

NOTICE:

w

THE THREE PULSE TEMPORAL PATTERN IS TO BE USED FOR EVACUATION USE ONLY.

w

THE SOUND OUTPUT FOR THE TEMPORAL 3 TONE IS RATED LOWER SINCE THE TIME THE HORN IS OFF IS AVERAGED INTO THE SOUND OUT PUT RATING.  WHILE THE HORN IS PRODUCING A TONE 

IN THE TEMPORAL 3 MODE ITS SOUND PRESSURE IS THE SAME AS THE CONTINUOUS MODE.  UNITS HAVE BEEN TESTED TO 0°C, 49°C AND 93% HUMIDITY.   

* Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 sound level required for public mode fire protection service.  

These settings are acceptable only for private mode fire alarm signaling use.  Use the high dBA setting for public mode applications (the chime tone is always private mode).

550-0011

Page 2

Strobe light can not be seen when objects such as doors, furniture or walls block strobe light.

NOTICE: 

w

THE VISUAL SIGNAL MUST BE IN THE DIRECT VIEWING AREA OF THE OCCUPANT IN ORDER TO BE SEEN.

w

VISUAL SIGNALS FOR THE HEARING IMPAIRED ARE ONLY ONE METHOD OF ALERTING THE HEARING IMPAIRED.  VISUAL SIGNALS MAY NOT BE THE PREFERRED METHOD 

FOR NOTIFYING ALL HEARING IMPAIRED INDIVIDUALS.

w

THE STROBE LIGHT MUST BE SEEN BY THE SLEEPING PERSON.  IF THE PERSON HAS HEAD TURNED OR OTHERWISE UNABLE TO BE ALERTED BY VISUAL, THE STROBE 

WILL NOT BE EFFECTIVE.

Содержание GEC24 Series

Страница 1: ...or outdoor or drip proof applications when used in conjunction with the GOE or GOELP Enclosure Wall mounted strobe and horn strobe appliances shall have their entire lens at heights above the finished...

Страница 2: ...ls Color Lens GECA24 GESA24 Amber GECB24 GESB24 Blue GECG24 GESG24 Green GECR24 GESR24 Red NOTICE DC VOLTAGE RANGE LIMITS 16 33V FWR VOLTAGE RANGE LIMITS 16 33V THIS PRODUCT WAS ONLY TESTED TO THE STA...

Страница 3: ...be lights will NOT be synchronized Place switches 1 and 2 in the ON position on the GEC24 GEC3 24 WGEC24 GECA24 GECB24 GECG24 GECR24 WGECA24 WGECB24 WGECG24 WGECR24 to power both the audible and visib...

Страница 4: ...STEM CONTROL PANEL OPERATING INSTRUCTIONS FOR PROPER OPERATION OF THE PANEL AND FIRE DETECTION SYSTEM SIGNALING APPLIANCE LIMITATION Your horn and horn strobe meet or exceed the current audibility req...

Страница 5: ...ORN DECIBEL AND CURRENT RATINGS PRODUCT INFORMATION HORN HORN STROBE NOTICE w THE NATIONAL BUILDING CODE AND CAN ULC S525 REQUIRES THAT ALL HORNS USED FOR BUILDING EVACUATION PRODUCE TEMPORAL CODED SI...

Страница 6: ...MONEY LOSS OF BUSINESS LOSS OF OPPORTUNITY LOSS OF GOODWILL AND LOSS OF REPUTATION THE MAXIMUM LIABILITY OF GENTEX SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE PAID BY YOU FOR THE APPLIANCE PLEASE...

Страница 7: ...pos s lorsqu ils sont utilis s avec les bo tiers GOE ou GOELP La lentille au complet des stroboscopes et des avertisseurs ou stroboscopes muraux doit tre plac e au dessus du plancher fini une hauteur...

Страница 8: ...s e maximum de 24 V RDA Courant de fonctionnement mA 1 15 105 164 30 130 196 60 203 325 75 243 355 110 310 491 Mod les Lentille color e GECA24 GESA24 Ambre GECB24 GESB24 Bleu GECG24 GESG24 Vert GECR24...

Страница 9: ...e fils d alimentation Pour alimenter l avertisseur et le stroboscope au moyen de sources d alimentation ind pendantes sur les mod les GEC24 GEC3 24 WGEC24 GECA24 GECB24 GECG24 GECR24 WGECA24 WGECB24 W...

Страница 10: ...NEMENT APPROPRI DU PANNEAU ET DU SYST ME DE D TECTION D INCENDIE LIMITES DE L APPAREIL DE SIGNALISATION L avertisseur et l avertisseur ou stroboscope sont conformes ou surpassent les exigences d audib...

Страница 11: ...COPE AVIS w LE CODE NATIONAL DU B TIMENT ET LA NORME CAN ULC S525 EXIGENT QUE TOUS LES AVERTISSEURS DESTIN S L VACUATION DU B TIMENT DIFFUSENT DES SIGNAUX TEMPORELS CODIFI S w LA PUISSANCE SONORE NOMI...

Страница 12: ...N CAS TRE SUP RIEURE AU PRIX D ACHAT DE L APPAREIL VEUILLEZ NOTER QUE CERTAINS TATS PAYS ET PROVINCES N AUTORISENT PAS L EXCLUSION OU LA LIMITATION DES DOMMAGES ACCIDENTELS OU CONS CUTIFS DE SORTE QUE...

Отзывы: