Instructions
Rev A
Procedure
16 Software
Update
Part No. 1258800
10
Click on the
Download
button.
11
When the
Kernel
file is at 100%, cycle the
power off, then back on at the red Emergency
Stop Button at the PCON.
12
Click on the
Exit
button, then the
Application
icon.
13
Select
Set All Defaults
. Select
Ok
.
14
When prompted, select
Level 2,
enter
SG81355
for the password and select
Accept
.
15
Cycle the power off, then back on at the red
Emergency Stop Button at the TCON.
16
Select
RSJ1AO Function Check
.
17
Enter the following settings:
Sensor voltage
range %, 60
.
Timeout, 10
.
Lower Deadband,
75
.
Min Movement Value, 22
.
18
When prompted, select
Level 2,
enter
SG81355
for the password and select
Accept
.
19
Push in the red Emergency Stop Button and
disconnect the DB9 cable from the PCON
PCB.
20
Close the platform control box and securely
tighten the retaining fasteners.
21
Calibrate the machine. Refer to the
appropriate Service Manual for you
machine.
Instructions
Part No. 1258800
Rev A
Software Update