Rev A
Instructions
Procedure
Part No. 1258800
Software Update
13
10
Cycle the power off, then back on at the red
Emergency Stop Button at the TCON.
11
Click on the
Application
icon.
12
Select
Set All Defaults
. Select
Ok
.
13
When prompted, select
Level 2,
enter
SG81355
for the password and select
Accept
.
14
Push in the red Emergency Stop Button and
disconnect the DB9 cable from the TCON
PCB.
15
Close the ground control box and securely
tighten the retaining fasteners.