ON
Configurable, writable
DIP 2
OFF
Normal
ON
Force the IP of converter to default IP 10.1.1.10
!
DIP 3
OFF
External watchdog invalid
ON
External watchdog is valid, recommended (more
stable)
DIP 4
OFF
Normal
ON
Reset the converter
DIP 5
OFF
Set visitor time / 60 seconds
ON
Set visitor time / 120 seconds
DIP 6-7
Reserved
DIP8
OFF
FPU8104
ON
shidean floor protocol
The time setting on sw5 is the total time from the start of the visitor to the elevator. It is 60
seconds when it is OFF, and 120 seconds when it is set to ON. It is based on the distance between
the gate and the elevator.
The SW8 of the FSC8105 is set to ON, the rest is set to OFF (as shown in the figure below),
At this time, the shidean protocol is used
_'
!
l
Switch
The FPU8105 detects the leveling signal of the first floor. If the elevator is on the first floor,
the corresponding LED will light up.
Figure 5-3 first floor signal
l
Communication
a)
4-channel 485 input
Following picture is wiring diagram between FSC8105 elevator group controller board and
Содержание LCM16-IP
Страница 5: ...1 4 Diagram...
Страница 6: ...l System wiring...
Страница 10: ...l PCB Dimension 20 L 14 5 W cm l Working temperature 20 C to 70 C l Relative humidity 5 to 95 2 4 Wiring...
Страница 11: ...2 5 socket define l PIN definition 0...
Страница 14: ...GB 34 P 7 2 V J V E W 0E 0...
Страница 29: ...3 Add permission in security groups...
Страница 30: ...Also can set the floor level Direct floor and visit floor 3 Add permission in personal list...
Страница 31: ...4 If you want to use visitor mode Aplease short IN10 and GND...
Страница 32: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk...