Under normal situation, the TX1 and RX1 indicators on the FPU8104 board are flashing
rapidly, and there is no alarm sound.
l
Relay input
In order to facilitate the docking of the building intercom and the intelligent elevator system,
a set of relay switch signal input (NO, COM) end is provided for the floor collector to connect the
intercom host signal.
l
switch
(
S1B
,
S1A
)
The FPU8104 detects the leveling signal of the first floor. If the elevator is on the first floor,
the corresponding LED will light up.
Functional test: After connecting the line according to the above figure, short the LAY1 and
GND of FSC8104, then connect the board S1A to 12V+, S1B to 12V-, (ie simulate the elevator to
the first floor), at this time the first floor layer of the elevator control board LPU8110 is turned on.
At the same time, the host computer has an event display.
l
Lay collection (LAY1-10)
FPU8104 has 10 sets of floor signal acquisition and output terminals, LAY1, GND, LAY2,
GND...LYA10, GND is 10 sets of switch signals, which are connected with the intercom
extensions on 1-10 floors.
Содержание LCM16-IP
Страница 5: ...1 4 Diagram...
Страница 6: ...l System wiring...
Страница 10: ...l PCB Dimension 20 L 14 5 W cm l Working temperature 20 C to 70 C l Relative humidity 5 to 95 2 4 Wiring...
Страница 11: ...2 5 socket define l PIN definition 0...
Страница 14: ...GB 34 P 7 2 V J V E W 0E 0...
Страница 29: ...3 Add permission in security groups...
Страница 30: ...Also can set the floor level Direct floor and visit floor 3 Add permission in personal list...
Страница 31: ...4 If you want to use visitor mode Aplease short IN10 and GND...
Страница 32: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk...