machines that set by the host. For example, if one host has 2 attached machines, the host is set to 2
(converted binary 10), and the attached machine address starts from 1. Setting as the following
picture
l
Communication
The communication between FPU8104 and group controller FSC8105 adopts RS485
communication mode;The communication between host FPU8104 and attached machines also
uses RS485. The following figure shows the wiring method of FSC8105 and one main two
attached FPU8104 board:
Figure 4-4 wiring
FSC8105 group control board 485+, 485- respectively connected with floor collector host
485+, 485-, FSC8105 host T/485A, T/485B and attached machine T/485A, T/485B corresponding
connection, attached machine and attached machine T/485A, T/485B corresponding connection.
l
Jumper settings
when the host and the attached machine used at the same time, and the communication
distance exceeds 100 meters, in order to increase the communication signal, it is recommended to
short the 485 jumper, and the following jumper is selected to the 485 state shorting diagram:
Содержание LCM16-IP
Страница 5: ...1 4 Diagram...
Страница 6: ...l System wiring...
Страница 10: ...l PCB Dimension 20 L 14 5 W cm l Working temperature 20 C to 70 C l Relative humidity 5 to 95 2 4 Wiring...
Страница 11: ...2 5 socket define l PIN definition 0...
Страница 14: ...GB 34 P 7 2 V J V E W 0E 0...
Страница 29: ...3 Add permission in security groups...
Страница 30: ...Also can set the floor level Direct floor and visit floor 3 Add permission in personal list...
Страница 31: ...4 If you want to use visitor mode Aplease short IN10 and GND...
Страница 32: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk...