Sec-3.13
Sensing Edges, Hardwired with Expansion Board:
Actuating the operator by using constant contact on the CLOSE button will override non-functioning
external reversing devices, including sensing edges.
WARNING
!
AVERTISSEMENT
!
L’activation de l’operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs
d’inversions externes, y compris les systèmes de détection des bords.
1/2 Door Height
+ 12in.
TCM or ESM Board
with ASO or MillerEdge
DC/T3 monitored edge
GND
MON
EDGE
Junction
Box
NOTE:
DO NOT use take up
reels with Monitored Edge
systems
Section 3: Wiring
1. Mount junction box to wall one half the door height plus 12 inches from floor.
2. Install hard-wiring from operator and coil cord to junction box and secure with conduit clamps.
3. Connect hard-wiring from operator to coil cord with wire nuts and install junction box cover plate.
4. Connect coil cord to sensing edge with wire nuts.
5. Install hard-wires to TCM or ESM in operator. (See instructions included with expansion boards for
detailed installation and wiring).
Miller Edge ‘DC’ Series & ASO Sentir GF Series Monitored
Sensing Edge Installation with Timer Control Module (TCM)
or Edge Sensing Module (ESM)