Sec-4.3
Section 4: Programming
Setting Close Direction:
The direction of motor rotation depends on mounting position and/or how the main input power phases are
wired. This setting is used to ensure the door is closing and opening according to the input commands.
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
SET CLOSE DIR
DID DOOR CLOSE?
YES NO
SCROLL KEY
NOTE:
Make sure door is in mid-travel.
FIG. 1
FIG. 2
FIG. 4
FIG. 3
HIT CLOSE KEY TO
TEST
1. If operator is in RUN mode, press CAL/RUN key to enter CALIBRATION MODE.
2. Use the SCROLL Key to scroll through the menu until SET CLOSE DIR is displayed. Press SET/CLR key.
3. Display will read HIT CLOSE KEY TO TEST. Briefly press the CLOSE key. FIG. 2 (Pressing the Scroll key at this
point will exit this function). * The display will read DID DOOR CLOSE >YES< NO FIG. 3.
4. Press SCROLL key (up or down) to toggle between YES and NO. FIG. 4. If YES is selected, no change to
operator calibration is made. If NO is selected, the board will change the operator’s down direction.
5. Press the SET/CLEAR key to make the selection. Display will read CLOSE DIR > SET and then UP LIMIT >
CLR.
6. Press CAL/RUN to return to run mode, or continue with LIMIT programming on next page.