16
Genie AWP Super Series
Part No. 37168
Operator’s Manual
First Edition • Ninth Printing
FUNCTION TESTS
Function Tests
Setup
1 Position the machine directly below the desired
work area.
2 Connect to the appropriate power source:
DC models: Connect battery pack.
AC models: Connect to a grounded 15A AC
power supply. Use a 12 gauge / 3.3mm
2
3-wire
grounded extension cord no longer than
50 feet / 13 m.
Air models: Connect the airline.
3 Insert the key and turn to the
ON
position OR
turn to platform control.
4 Pull out the red Emergency Stop button to the
ON
position at the ground controls.
5 Twist to release the red Emergency Stop button
at the platform controls.
Result: AC & DC models: The power light should
come on.
Air models: The air
pressure gauge should
read 80-110 psi /5.5 -
7.8 bar.
6 Select an outrigger and
slide it into a base
socket until the
outrigger lock pin snaps
into place. Adjust the
outrigger to level the
machine and raise the
base casters slightly off
the ground. Level the
machine using only the
outriggers. Do not use
chocks, blocks or shims
to level the machine.
7 Check the interlock display lights at the ground
controls. Confirm that the corresponding light is
on.
8 Repeat this procedure for each of the remaining
outriggers.
9 Use the bubble level and adjust the leveling
jacks until the machine base is level.
Test Emergency Stop
10 Push in the red Emergency Stop button at the
ground controls to the
OFF
position.
11 Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
ANSI & CSA
CE
a
control activate button
b
up/down switch
Result: The up/down function should not
operate.
a
b
a
b