![Genie CCTV MDVR4SD Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/genie-cctv/mdvr4sd/mdvr4sd_user-manual_2212562045.webp)
45
5.4.6 RELAY
OUTPUT
In the EVENT menu,
Move the cursor to “RELAY OUTPUT” using
the
▲
,
▼
buttons.
Press the ENTER button when the cursor is
on “RELAY OUTPUT” and the following
screen appears.
Move the cursor using the
▲
,
▼
buttons and
set up the value using the
button.
To exit this screen, press the “ESC” button
NOTE:
It’s possible to set the RELAY OUTPUT for the type of event, and it‘s possible to set the period of the
relay output from 1 to 30 seconds.
POWER (N.C), USER, REC, NOT USED, ALARM, LOSS, MOTION and HDD ERROR are available
and you can select any one of the eight.
z
POWER:
The relay operates when power is off/lost.
z
USER:
User can operate the relay output manually by pressing the “FUNCTION” button
with (+) button
and
(-) button.
NC (Normally Closed)
→
NO: press the (+) button with the “FUNCTION” button.
NO (Normally Open)
→
NC: press the (-) button with the “FUNCTION” button.
Press the “FUNCTION” button again if you want to exit this mode.
(you can also use this function through the network viewer.)
z
REC:
The relay operates when the unit starts recording.
z
NOT USED:
If you do not want to use this function, select “NOT USED”
z
ALARM:
The relay operates when the unit receives an alarm.
z
LOSS:
The relay operates when video loss occurs.
z
MOTION:
The relay operates when motion is detected.
z
HDD ERROR:
The relay operates if storage problems occur.