background image

5. Powering the module

An AC/DC adapter is provided with each OCG-16m module with the following specifications:

AC input voltage range:

90 - 264 V-AC

AC input frequency:

47 - 63 Hz

DC output voltage:

nominal 12V-DC, max 14.4 V-DC

DC output current:

min. 1.25 A

The connection scheme of the DC-plug is indicated in Figure 5.

Figure 5

DC plug connection scheme

6. Overview of LED performance monitors

The OCG-16m  module  is  equipped  with  a  variety  of  LED indicators,  as  shown  in   Figure  6,

providing the user with an efficient tool to check the correct operation of the OCG-16m:

Power LED (top-left):

This LED lights up green to indicate that the AC/DC adapter is connected correctly.

WAN LED (middle-left):

This   LED   lights   up   yellow   when   the   optical   input   power   at   the   WAN   port   is   within

specification to indicate a good fiber connection to the Central Office.

RTV LED (bottom-left):

This LED will light up yellow to indicate that a CATV signal is present (in case an OCG-

12m CATV receiver is present).

Tel1 LED (middle-right):

This LED will light up yellow to indicate when telephone line 1 is registered; during a

firmware upgrade this LED will flash.

Tel2 LED (bottom-right):

This LED will light up yellow to indicate when telephone line 2 is registered; during a

firmware upgrade this LED will flash.

Figure 6

OCG-16m LED indicators

Nov 2005, Genexis B.V., Lodewijkstraat 1A, 5652 AC Eindhoven, The Netherlands, www.genexis.nl

Genexis

Genexis

-

+

-

+