Important notes: 

Genexis does not assume responsibility for products that are not handled according to the
instructions contained in this user manual.

Any claim for warranty or repair will be void when:

Opening the OCG-16m data/voice module or the OCG-12m CATV module.

An attempt is made to modify, retrieve or reverse-engineer the software contained in
the OCG-16m data/voice module.

For   the   software,   contained   in   the   OCG-16m   data/voice  module,   the   OCG-16m   software
license agreement is applicable; a copy of this license agreement is available upon request. 

3. Module user specification

General

Power supply: 

12 V DC nominal, 14.4 V DC max

Power dissipation:

7 Watt typical, 15 Watt max

Operating conditions: 

0 – 35 °C

Storage conditions: 

0 – 70 °C

OCG-16m user telephone interface (RJ-11)

2x RJ-11 connectors

2x analog POTS line, each supporting 5 REN

SIP based Voice-over-IP (rfc 3261)

Speech codec G.711 (uncompressed)

Standard Fax (G3) supported

OCG-16m user data interface (RJ-45)

4x 10/100Base-TX (IEEE 802.3 Ethernet) RJ-45 connectors

Full/half duplex

Auto-negotiating

Auto-MDI/MDIX

Range 100 meters

OCG-12m user interface (F-connector)

1x F-female connector (IEC 169-24)

RF frequency range 47 - 862 MHz

Nov 2005, Genexis B.V., Lodewijkstraat 1A, 5652 AC Eindhoven, The Netherlands, www.genexis.nl