4. Installation instructions for OCG-16m (and optionally OCG-12m)
1. Housing installation
There are 2 possible cases: either a complete FXP-10 housing is already installed or the
OCG-16m will be installed simultaneously with a FXP-10 housing.
In case a FiberXport housing is already installed, it needs to be opened by removing the seal
(if present), unscrewing the locking screw on the front and removing the white cover.
In case a FiberXport housing is to be installed together with OCG-16m module, please follow
the installation instructions for the housing (separately available).
In both cases the small covering plate at the right side of the white cover (as shown in Figure
1) needs to be removed by pushing it out from the inside of the cover.
Figure 1
Removal of covering plate
2. Mounting the OCG-12m CATV-receiver (Figure 2)
In case a CATV-receiver needs to be added, attach this module first. Place the module
directly onto the white base-plate, by positioning it on the four centering pins. Ensure the
module is correctly positioned to enable a good connection to the data/voice module (see 3.)
3. Mounting the OCG-16m data/voice unit (Figure 3)
Before attaching the OCG-16m data/voice module, please verify that the fibers are spooled
and stored on the baseplate at the right hand side of the 3 fiber guiding stubs. In particular
verify that a fiber is not positioned over the OCG-16m fixation pin hole or the cover screw
hole in the baseplate as shown in Figures 2 and 4.
Slide the OCG-16m data/voice unit directly onto the baseplate as shown in Figure 3, using
the sliding guides. Make sure that the OCG-16m fixation pin is clicked into the baseplate as
shown in Figure 4.
Automatically, a power connection is made with the CATV-receiver (if included).
Note:
make sure that the OCG-16m data/voice unit is pressed tightly onto the CATV-receiver
module, to ensure a good electrical connection.
4. Connecting the fiber cables
The incoming fiber cables should be equipped with a blue SC/PC connector for the data fiber
and a green SC/APC connector for the CATV fiber. Connect the blue SC/PC connector to the
OCG-16m data/voice unit by plugging the connector into the black receptical. Connect the
green SC/APC connector to the OCG-12m CATV-receiver by plugging the connector into the
metallic receptical. Ensure the connectors fit snugly to enable a good optical connection.
Note:
the installer should ensure that the appropriate optical power levels are present at the
output connectors of both fiber cables.
5. Activating the module
First, connect the DC-plug of the AC/DC adapter to socket at the right hand side of the
FiberXport
®
OCG-16m module. Then connect the adapter to the 220V mains socket. The
green power LED should light up to indicate proper operation of the module power supply.
Nov 2005, Genexis B.V., Lodewijkstraat 1A, 5652 AC Eindhoven, The Netherlands, www.genexis.nl
Genexis
Genexis
Press out
covering plate