4. Installation instructions for OCG-16m (and optionally OCG-12m)

1. Housing installation

There are 2 possible cases: either a complete FXP-10 housing is already installed or the

OCG-16m will be installed simultaneously with a FXP-10 housing.

In case a FiberXport housing is already installed, it needs to be opened by removing the seal

(if present), unscrewing the locking screw on the front and removing the white cover.

In case a FiberXport housing is to be installed together with OCG-16m module, please follow

the installation instructions for the housing (separately available).

In both cases the small covering plate at the right side of the white cover (as shown in Figure

1) needs to be removed by pushing it out from the inside of the cover.

Figure 1

Removal of covering plate

2. Mounting the OCG-12m CATV-receiver (Figure 2)

In   case   a   CATV-receiver   needs   to   be   added,   attach   this   module   first.   Place   the   module

directly onto the white base-plate, by positioning it on the four centering pins. Ensure the

module is correctly positioned to enable a good connection to the data/voice module (see 3.)

3. Mounting the OCG-16m data/voice unit (Figure 3)

Before attaching the OCG-16m data/voice module, please verify that the fibers are spooled

and stored on the baseplate at the right hand side of the 3 fiber guiding stubs. In particular

verify that a fiber is not positioned over the OCG-16m fixation pin hole or the cover screw

hole in the baseplate as shown in Figures 2 and 4.

Slide the OCG-16m data/voice unit directly onto the baseplate as shown in Figure 3, using

the sliding guides. Make sure that the OCG-16m fixation pin is clicked into the baseplate as

shown in Figure 4.

Automatically, a power connection is made with the CATV-receiver (if included). 

Note: 

make sure that the OCG-16m data/voice unit is pressed tightly onto the CATV-receiver

module, to ensure a good electrical connection.

4. Connecting the fiber cables

The incoming fiber cables should be equipped with a blue SC/PC connector for the data fiber

and a green SC/APC connector for the CATV fiber. Connect the blue SC/PC connector to the

OCG-16m data/voice unit by plugging the connector into the black receptical. Connect the

green SC/APC connector to the OCG-12m CATV-receiver by plugging the connector into the

metallic receptical. Ensure the connectors fit snugly to enable a good optical connection.

Note: 

the installer should ensure that the appropriate optical power levels are present at the

output connectors of both fiber cables.

5. Activating the module

First, connect the DC-plug of the AC/DC adapter to socket at the right hand side of the

FiberXport

®

  OCG-16m module. Then  connect the adapter to the 220V mains socket. The

green power LED should light up to indicate proper operation of the module power supply.

Nov 2005, Genexis B.V., Lodewijkstraat 1A, 5652 AC Eindhoven, The Netherlands, www.genexis.nl

Genexis

Genexis

Press out 

covering plate