Note:
All models are available with a built-in Class A Industrial Standard RFI Filter. Contact Sales Department.
51
F29 – CPU Program Version
Factory Setting: Current Software Version –
F29 is used to display the software
version of the drive.
F30 – Logs Last 3 Faults that Occurred
F30 logs the last three faults that occurred, in chronological order. Press the key
to scroll through the three faults that occurred. The decimal point in the display
indicates the chronological occurrence of the fault (“x.xx” indicates the latest fault
that occurred. “xx.x” indicates the previous fault that occurred. “xxx.” indicates
the first fault that occurred). Press the
▼
/RESET key to erase all three recorded
faults (“-.- - ”, “- -.-”, and “- - -.” will be displayed when the key is pressed). See
Table 17, on pages 49 and 50.
X.
OPTIONAL ACCESSORIES
A. DIN Rail Mounting Kit (Part No. 14000) –
Available for all models except
KBE2-1125-4, 1150-4, 1101-4, 2101-4, 2202-4, 2203-4, 4301-4, 4302-4,
4303-4.
B. Class B Residential Standard RFI (EMI) Filters –
Provides RFI noise suppres-
sion and complies with CE Directive 89/336/EEC relating to the EMC Class B
Residential Standard. See Table 19 and Figure 19, on page 52. The recom-
mended maximum wiring distance between drive and filter is 12” (30 cm).
Display
Indication
Description
SP0
The drive has been set to Zero Frequency using the keypad or external frequency
command.
SP1
The drive is in Stop Mode due to an interruption and resumption of the AC power.
To restart the drive, open and close the Start/Stop contact.
Note:
F28 is set to “001” [Disable Automatic AC Line Start] (factory setting).
SP2
The RUN/STOP key is pressed while the drive is in the Run Mode.
TABLE 18 – STATUS INDICATORS WHEN THE DRIVE IS IN
EXTERNAL START/STOP MODE (F10 = 001)
Part
No.
Rating
Drive Model
Dimensions
Inches
mm
14020
10 Amps @ 230 Volts AC –1
φ
All 230 Volt AC thru 1 HP
2.99 x 6.14 x 0.98
76 x 156 x 25
14012
20 Amps @ 230 Volts AC – 1
φ
All 230 Volt AC thru 3 HP
4.84 x 6.81 x 1.54
123 x 173 x 39
14015
10 Amps @ 460 Volts AC – 3
φ
All 380/460 Volt AC thru 3 HP 4.84 x 6.81 x 1.54
123 x 173 x 39
TABLE 19 – CLASS B RESIDENTIAL STANDARD RFI FILTERS