![Genesis KBE2 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/genesis/kbe2/kbe2_installation-and-operation-manual_2211094011.webp)
11
Description
Parameter / Range
Factory
Setting
AC Line Input Voltage (VAC)
115 & 208/230 (±15%),
380 - 460 (±10%)
—
Input Line Frequency Range (Hz)
48 - 62
—
Output Waveform
Sine Coded PWM
—
Frequency Range (Hz)
0.1 - 200
60
Switching Frequency Range (kHz)
4 - 16
8
Frequency Resolution (Hz Increments)
0.1 up to 100 Hz and
1.0 from 100 Hz thru 200 Hz
—
Acceleration/Deceleration Range (Seconds)
0.1 - 999
5.0
Overvoltage Trip Point @ 230 VAC, @ 460 VAC (VAC)
290, 580
—
Undervoltage Trip Point @ 230 VAC, @ 460 VAC (VAC)
140, 280
—
Overload Rating (% for 1 Minute)
150
—
Minimum Frequency Range (Hz)
0.0 - 200
0.0
Maximum Frequency Range (Hz)
1.0 - 200
60.0
Braking Torque without Braking Resistor (%)
1
20
20
Braking Torque with Braking Resistor (%)
2
20 - 130
4
20
Operating Temperature Range (ºC)
-10 to 50
—
Humidity (Relative, Non-Condensing) (%)
0 - 95
—
Maximum Vibration (G)
1
—
Output Relay Contact Rating
1 Amp @ 30 Volts DC,
250 Volts AC
—
External Analog Signal Input
0 - 10 VDC,4 - 20 mADC,
0 - 20 mADC
0 - 10 VDC
Remote Speed Potentiometer (
Ω
)
5k or 10k
—
Analog Output Voltage (Volts DC)
3
0 - 10
—
Built-In EMC Filter Specification (“F” Suffix Models)
Class A Industrial
—
TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
Notes: 1.
Models KBE2-1125-P, 1150-P, 2150-P, 2101-P do not contain a braking transistor.
2.
Models KBE2-
2202, 2203, 4301, 4302, and 4303 require optional brake resistor to achieve maximum braking. Maximum brak-
ing torque varies with model.
3.
Proportional to the Output Frequency Upper Limit set with F06.
Sec. I – Introduction (Cont.)
Содержание KBE2