LUBRICATION POINTS
4
5
3
2
1
Use a lithium-based premium EP #2 in normal conditions above 32° F (0° C). Use Grade 0 in tem-
peratures below freezing.
Grease all fittings every eight hours of operation. Grease until extrusion is visible. Grease at the
end of the shift when the attachment is warm.
After greasing the rotation bearing, rotate the attachment through two full rotations.
Grease locations:
1. Front cylinder pin
2. Rear cylinder pin
3. Pivot group
4.
Remote grease fitting for rotation bearing
5. Gear teeth inside bearing shroud
!
DANGER
Shut off excavator or skid steer and disable hydraulics
per OEM instructions before greasing.