Use the diagram above to identify the part which is required. To order parts call the number 
listed below or call your local contractor. 

Fig. 7 

 Exploded View and Parts List

 

Description 

Part Number 

1  Fan Motor 

EACCM7-01 

2  Fan Blade 

EACCM7-02 

3  Copper Contact 

EAC14-08 

4  Fibreboard (with 2 Copper Contacts) 

EACCM7-04 

5  Intake Grill 

EACCM7-05 

6  Cover Assembly (incl. Grill) (White) 

EACCM7-06W 

6a  Cover Assembly (incl. Grill) (Gray) 

EACCM7-06G 

7  Collecting Cell 

EACCM7-07 

8  Cell Handle 

EAC14-16 

9  Ionizing Wire 

EAC20-19 

10  Safety Interlock Switch 

EACCM13-10 

11  Red Indicator Light 

EACCM13-11 

Description 

Part Number 

12  Power Switch (Gray) 

EACCM13-12W 

12a  Power Switch (Black) 

EACCM13-12G 

13  3-Position Slide Switch (Gray) 

EACCM13-13W 

13a  3-Position Slide Switch (Black) 

EACCM13-13G 

14  Power Board Fibreboard 

EACCM13-14 

15  Power Board 

EACCM13-15 

16  24 Volt Transformer 

EACCM13-16 

17  Cell Guide 

EAC14-14 

18  Prefilter 

EACCM13-18 

19  Remote Switch Box

 

EACCM13-19 

20  Door Label (Close Door Latch...) 

EACCM13-20 

21  Dax Detergent 

9900 

10 

Содержание SSCB-7 SERIES

Страница 1: ...Operation And Maintenance Manual SSCB 7 SERIES SEMI FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE INSTALLING OPERATING CLEANING OR SERVICING UNIT...

Страница 2: ...ple of Electrostatic Precipitation Millions of airborne pollutants are drawn through the intake grill on the bottom of the Air Cleaner and first pass through a Prefilter which removes all large visibl...

Страница 3: ...e wiring compartment INSTALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be...

Страница 4: ...ing is an average wash cycle Stores Offices Computer Conference Rooms 4 Weeks Cafeterias Restaurants Lounges 3 4 Weeks Bars Bingo halls 1 3 Weeks The unit should be checked on a regular basis to deter...

Страница 5: ...tch and transformer to make sure that they are functioning correctly 6 If there is voltage present but the performance light does not come on replace the light 7 The high voltage can be adjusted with...

Страница 6: ...lead with the two white leads from the terminal block and connect with the wire nut you removed earlier 10 Replace power box cover panel and close cover 11 Turn ON the power to the Air Cleaner and te...

Страница 7: ...until a replacement is received 4 Place one end of the loop over the finger at the bottom of the cell 5 Using needle nose pliers grip the other end of wire near the bottom of the top loop Pull the wi...

Страница 8: ...Fig 6 Electrical Schematic With Wired Remote 120 Volt Fig 5 Electrical Schematic 120 Volt 8...

Страница 9: ...mance indicator light is ON Defective power switch Check power switch for continuity with ohmmeter Replace if defective Defective speed selector switch Check switch for continuity with ohmmeter Replac...

Страница 10: ...ncl Grill Gray EACCM7 06G 7 Collecting Cell EACCM7 07 8 Cell Handle EAC14 16 9 Ionizing Wire EAC20 19 10 Safety Interlock Switch EACCM13 10 11 Red Indicator Light EACCM13 11 Description Part Number 12...

Страница 11: ...in 71 0 cm Height 15 in 38 1 cm Weight 70 0 lbs 32 0 kg Input Voltage 120 V 60 Hz Power Consumption maximum 150 Watts Air Flow Hi 712 CFM 1210 m3 hr Medium 575 CFM 977 m3 hr Low 440 CFM 748 m3 hr Moto...

Страница 12: ...General Filters Inc THERE ARE NOT EXPRESS WARRANTIES COVERING THIS ELECTRONIC AIR CLEANER OTHER THAN AS SET FORTH ABOVE THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE A...