GeneralAire Elite 1000 Скачать руководство пользователя страница 3

This humidifier, if properly registered by the return of the warranty registration card to the manufacturer, is warranted to the consumer against defects in 
materials and workmanship for a period of ten years from the date of installation.  Evaporator pads, water strainers or metering orifices are not covered by 
this limited warranty or any other warranties.  Any other defective parts will be repaired without charge except for removal, reinstallation and 
transportation costs.  To obtain repair service under this limited warranty, the consumer must send the defective part or the complete humidifier to the 
manufacturer.

THERE ARE NO EXPRESS WARRANTIES COVERING THIS AIR CLEANER OTHER THAN AS SET FORTH ABOVE, THE IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.  THE MANUFACTURER ASSUMES NO 
LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN THIS LIMITED WARRANTY.  THE 
MANUFACTURER WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.

This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  Some states do not allow either 
limitations on implied warranties, or exclusions from incidental or consequential damages, so the above exclusion and limitation may not apply to you.

Any questions pertaining to this limited warranty should be addressed to the manufacturer.  (U.S.A.:  The manufacturer has elected not to make available 
the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.)

Your Humidifier is engineered to give helpful and trouble-free humidification.  For maximum efficiency the following cleaning procedures should be carried 
out at the end of each heating season:

1. Turn off water supply and electrical power to humidifier.
2. Remove cover, water distributor trough, evaporator pad, pad rails and drain pan.  Clean excessive mineral   
    deposits from the distributor trough, drain pan, pad rails and humidifier cabinet.  A solution of 1/2 vinegar & 1/2  
    water will help loosen mineral deposits.  Inspect drain hose, clean or replace as necessary.
3. Replace humidifier evaporator pad if necessary. (Part number GA19) Install trough, pad rails and drain pan.               
    Replace cover, reconnect electrical plug. Replace evaporator pad yearly for peak performance.
4. In heavy mineral areas or if the solenoid valve fails to function disconnect the 1/4” water supply line from the  
    solenoid valve.  Carefully pull the strainer screen (P.N. 900-8) from the valve body (P.N. 900-6).  Clean the  
    mineral deposits from all parts.   If the orifice is clogged, it may be opened by inserting a small pin.  Reinsert  
    the filter into the valve body.
5. Reconnect the 1/4” water line to the solenoid valve if necessary.  Turn on the water supply and check all points  
    for leakage.  The operation of the unit may be checked by starting the furnace.  The humidifier operates only  
   when the furnace blower is running or the burner circuit is energized.  The humidifier is now ready for  
   operation.
6. During the summer, turn off water supply and electrical power to humidifier.

CARE AND MAINTENANCE

LIMITED WARRANTY

 

AT

OUTSIDE

TEMPERATURE

RECOMMENDED
SETTING

-20

°

F  -29

°

C

15%

-10

°

F  -23

°

C

20%

0

°

F  -18

°

C

25%

+10

°

F  -12

°

C

+20

°

F   - 7

°

C

30%
35%

+30

°

F   - 1

°

C

40%

PARTS LIST FOR HUMIDIFIER

GA4237 MOTOR
900-71 NAMEPLATE

900-9 NOZZLE
900-10 SPOUT

900-40 PAD RAIL
GA19 EVAPORATOR PAD
900-15 DISTRIBUTOR TROUGH
GA4247 FAN BLADE

GA4231 ORIFICE - YELLOW
P-190 COMPRESSION SLEEVE (PLASTIC)/P102 COPMRESSION SLEEVE (BRASS)
P-101 COMPRESSION NUT
GA4235 DISTRIBUTOR TUBE

P-189 TUBE SUPPORT
P-101 COMPRESSION NUT
P-102 COMPRESSION SLEEVE (BRASS) OR
P-190 COMPRESSION SLEEVE (PLASTIC)
GA4004 STRAINER SCREEN

GA4045 SOLENOID & HARNESS 
ASSEMBLY

900-14 DRAIN PAN

1000-11 HARNESS - BOARD
GA4238 RELAY ASS'Y
1137-31 POWER SUPPLY CORD

Содержание Elite 1000

Страница 1: ... self tapping saddle valve on either a cold or a hot water pipe A side or top mount is best to avoid clogging from pipe sediment Connect 1 4 O D tubing to the saddle valve Copper tubing requires a brass compression nut and brass sleeve Plastic tubing requires a brass insert inside the tubing in addition to a plastic ferrule and brass nut NOTE DO NOT USE PLASTIC TUBING ON HOT WATER OR IN CONTACT WI...

Страница 2: ... may be wired from a continuous 115 volt power source Install the on off switch in series with the hot or black wire Install the GA50 Current Sensing Relay in series with the humidistat circuit The Current Sensing Relay will detect furnace operation and supply power to the humidifier accordingly 7 7 5 GFX3 ELECTRONIC HUMIDISTAT Turn on water supply and plug in power cord to check operation of humi...

Страница 3: ...d electrical power to humidifier 2 Remove cover water distributor trough evaporator pad pad rails and drain pan Clean excessive mineral deposits from the distributor trough drain pan pad rails and humidifier cabinet A solution of 1 2 vinegar 1 2 water will help loosen mineral deposits Inspect drain hose clean or replace as necessary 3 Replace humidifier evaporator pad if necessary Part number GA19...

Страница 4: ...ifier will not operate Humidifier runs without furnace operation or humidifier never shuts off Proper voltage present at solenoid valve 24 VAC but no water flow Too much humidity in home and or condensation on windows 1 Set thermostat to operate both furnace burner and blower Operation may be necessary for system power 2 Humidity level in home may be higher than humidistat setting Increase humidit...

Страница 5: ... 16 1 2 ELITE 1000 HUMIDIFIER SPECIFICATIONS Model 1000A GFI 5730 includes Humidifier components GA19 Vapor pad Solenoid Assembly Relay Circuit Board Fan Motor Fan Blades Accessories GFX3 Automatic Digital Humidistat Code Valve Saddle Valve Model 1000M GFI 5735 includes Humidifier Components GA19 Vapor Pad Solenoid Assembly Relay Circuit Board Fan Motor Fan Blades Accessories Manual Humidistat Sad...

Страница 6: ...____________________________________________________________ Address ____________________________________________________________________ Address 2 ___________________________________________________________________ City _____________________ State ___________ Zip Code _______________________ Contractor Phone ____________________________________________________________ Contractor Email ___________...

Страница 7: ... tuyau d un diam ext de 6 mm 1 4 po au robinet vanne à étrier Les tuyaux en cuivre exigent un écrou à compression et un manchon en laiton Les tuyaux en plastique exigent un insert en laiton à l intérieur des tuyaux ainsi qu une virole en plastique et un écrou en laiton REMARQUE NE PAS UTILISER DE TUYAUX EN PLASTIQUE AVEC DE L EAU CHAUDE OU SUR UNE SURFACE DE CONTACT CHAUDE DE PLÉNUM OU DE CONDUIT ...

Страница 8: ...a le fonctionnement de l appareil de chauffage et fournira l alimentation électrique nécessaire à l humidificateur 5 HUMIDISTAT ÉLECTRONIQUE GFX3 Ouvrir l alimentation en eau et brancher le cordon d alimentation pour vérifier le fonctionnement de l humidificateur Régler l humidistat en mode de demande Lorsque l appareil de chauffage est éteint la vanne électromagnétique doit être fermée et le vent...

Страница 9: ...tributeur du bac de récupération des rails du tampon et du boîtier de l humidificateur Une solution moitié vinaigre moitié eau aide à déloger les dépôts de minéraux Inspecter le tuyau de l égouttoir le nettoyer ou le remplacer au besoin 3 Remplacer le tampon d évaporation de l humidificateur si nécessaire réf GA19 Installer la goulotte les rails de tampon et le bac de récupération Remettre en plac...

Страница 10: ...tique est bonne 24 V c a mais l eau ne coule pas Taux d humidité trop élevé dans la maison ou présence de condensation sur les fenêtres 1 Régler le thermostat de manière à faire fonctionner l appareil de chauffage et le ventilateur il peut être nécessaire que ces appareils fonctionnent pour alimenter le système 2 Le niveau d humidité de la maison peut être plus élevé que le réglage de l humidistat...

Страница 11: ...n mètres carrés pieds carrés et le type de construction ACCESSOIRES DES COMPOSANTS DE L HUMIDIFICATEUR EMBALLÉ Cadre de l humidificateur avec la découpe du plénum illustrée en lignes pointillées 30 8 cm 12 1 8 po 35 9 cm 14 1 8 po Nº de modèle Faible 0 75 CAH GPD Moyen 0 50 CAH Élevé 0 30 CAH Elite 570 12 74 m2 800 pi2 111 m2 1200 pi2 186 m2 2000 pi2 Elite 900 17 104 m2 1115 pi2 153 m2 1650 pi2 26...

Страница 12: ..._________________________ Adresse __________________________________________________________________ Adresse 2 ________________________________________________________________ Ville ____________________ État Province _____________ Code postal _________ Téléphone ________________________________________________________________ Courriel _______________________________________________________________...