GeneralAire Elite 1000 Скачать руководство пользователя страница 12

Renseignements sur le produit :

Numéro de série : ____________________________________________________________

Modèle :  ___________________________________________________________________

Date d’installation :  Mois _______________   Jour ______________   Année ____________

Renseignements sur le propriétaire :

Nom :  _____________________________________________________________________

Adresse :    __________________________________________________________________

Adresse 2 :    ________________________________________________________________

Ville :   ____________________  État/Province :  ___________   Code postal :    ___________

Téléphone :   ________________________________________________________________

Courriel :    __________________________________________________________________

ENREGISTREMENT DE LA GARANTIE

Renseignements sur l’installateur :

Nom :  _____________________________________________________________________

Adresse :    __________________________________________________________________

Adresse 2 :    ________________________________________________________________

Ville :   ____________________  État/Province :  _____________   Code postal :    _________

Téléphone :   ________________________________________________________________

Courriel :   __________________________________________________________________

Le produit peut être enregistré en ligne au www.GeneralAire.com 

ou par la poste en envoyant le formulaire ci-dessous

Poster le formulaire à :

General Filters, Inc

Attn: Warranty Dept.

43800 Grand River Ave.

Novi, MI 48375, É.-U.

découper le long de la ligne pointillée

découper le long de la ligne pointillée

CLIENTS AUX É.-U.
General Filters, Inc.
43800 Grand River Ave.
Novi, MI 48375, É.-U.
www.GeneralAire.com
[email protected]
Numéro sans frais : 866-476-5101

CLIENTS AU CANADA
Canadian General Filters, Ltd.
400 Midwest Rd.
Toronto, ON  M1P3A9 Canada
www.CGFProducts.com
[email protected]
Tél. : 416-757-3691

ASSISTANCE TECHNIQUE

R

Qualité de l’air frais intérieur

Содержание Elite 1000

Страница 1: ... self tapping saddle valve on either a cold or a hot water pipe A side or top mount is best to avoid clogging from pipe sediment Connect 1 4 O D tubing to the saddle valve Copper tubing requires a brass compression nut and brass sleeve Plastic tubing requires a brass insert inside the tubing in addition to a plastic ferrule and brass nut NOTE DO NOT USE PLASTIC TUBING ON HOT WATER OR IN CONTACT WI...

Страница 2: ... may be wired from a continuous 115 volt power source Install the on off switch in series with the hot or black wire Install the GA50 Current Sensing Relay in series with the humidistat circuit The Current Sensing Relay will detect furnace operation and supply power to the humidifier accordingly 7 7 5 GFX3 ELECTRONIC HUMIDISTAT Turn on water supply and plug in power cord to check operation of humi...

Страница 3: ...d electrical power to humidifier 2 Remove cover water distributor trough evaporator pad pad rails and drain pan Clean excessive mineral deposits from the distributor trough drain pan pad rails and humidifier cabinet A solution of 1 2 vinegar 1 2 water will help loosen mineral deposits Inspect drain hose clean or replace as necessary 3 Replace humidifier evaporator pad if necessary Part number GA19...

Страница 4: ...ifier will not operate Humidifier runs without furnace operation or humidifier never shuts off Proper voltage present at solenoid valve 24 VAC but no water flow Too much humidity in home and or condensation on windows 1 Set thermostat to operate both furnace burner and blower Operation may be necessary for system power 2 Humidity level in home may be higher than humidistat setting Increase humidit...

Страница 5: ... 16 1 2 ELITE 1000 HUMIDIFIER SPECIFICATIONS Model 1000A GFI 5730 includes Humidifier components GA19 Vapor pad Solenoid Assembly Relay Circuit Board Fan Motor Fan Blades Accessories GFX3 Automatic Digital Humidistat Code Valve Saddle Valve Model 1000M GFI 5735 includes Humidifier Components GA19 Vapor Pad Solenoid Assembly Relay Circuit Board Fan Motor Fan Blades Accessories Manual Humidistat Sad...

Страница 6: ...____________________________________________________________ Address ____________________________________________________________________ Address 2 ___________________________________________________________________ City _____________________ State ___________ Zip Code _______________________ Contractor Phone ____________________________________________________________ Contractor Email ___________...

Страница 7: ... tuyau d un diam ext de 6 mm 1 4 po au robinet vanne à étrier Les tuyaux en cuivre exigent un écrou à compression et un manchon en laiton Les tuyaux en plastique exigent un insert en laiton à l intérieur des tuyaux ainsi qu une virole en plastique et un écrou en laiton REMARQUE NE PAS UTILISER DE TUYAUX EN PLASTIQUE AVEC DE L EAU CHAUDE OU SUR UNE SURFACE DE CONTACT CHAUDE DE PLÉNUM OU DE CONDUIT ...

Страница 8: ...a le fonctionnement de l appareil de chauffage et fournira l alimentation électrique nécessaire à l humidificateur 5 HUMIDISTAT ÉLECTRONIQUE GFX3 Ouvrir l alimentation en eau et brancher le cordon d alimentation pour vérifier le fonctionnement de l humidificateur Régler l humidistat en mode de demande Lorsque l appareil de chauffage est éteint la vanne électromagnétique doit être fermée et le vent...

Страница 9: ...tributeur du bac de récupération des rails du tampon et du boîtier de l humidificateur Une solution moitié vinaigre moitié eau aide à déloger les dépôts de minéraux Inspecter le tuyau de l égouttoir le nettoyer ou le remplacer au besoin 3 Remplacer le tampon d évaporation de l humidificateur si nécessaire réf GA19 Installer la goulotte les rails de tampon et le bac de récupération Remettre en plac...

Страница 10: ...tique est bonne 24 V c a mais l eau ne coule pas Taux d humidité trop élevé dans la maison ou présence de condensation sur les fenêtres 1 Régler le thermostat de manière à faire fonctionner l appareil de chauffage et le ventilateur il peut être nécessaire que ces appareils fonctionnent pour alimenter le système 2 Le niveau d humidité de la maison peut être plus élevé que le réglage de l humidistat...

Страница 11: ...n mètres carrés pieds carrés et le type de construction ACCESSOIRES DES COMPOSANTS DE L HUMIDIFICATEUR EMBALLÉ Cadre de l humidificateur avec la découpe du plénum illustrée en lignes pointillées 30 8 cm 12 1 8 po 35 9 cm 14 1 8 po Nº de modèle Faible 0 75 CAH GPD Moyen 0 50 CAH Élevé 0 30 CAH Elite 570 12 74 m2 800 pi2 111 m2 1200 pi2 186 m2 2000 pi2 Elite 900 17 104 m2 1115 pi2 153 m2 1650 pi2 26...

Страница 12: ..._________________________ Adresse __________________________________________________________________ Adresse 2 ________________________________________________________________ Ville ____________________ État Province _____________ Code postal _________ Téléphone ________________________________________________________________ Courriel _______________________________________________________________...