En-7

AIR CLEANING OPERATION

Example: 

When set to AUTO.

Use this function to remove airborne impurities such as dust, tobacco smoke and pollen and clean the air of the room.

The air cleaning operation can be used alone or combined with cooling, heating and dry (dehumidifying) operations.

Starting air cleaning operation

1

Start the operation in any one of the following: AUTO,
COOL, HEAT, DRY or FAN.

Refer to pages 5 and 6 for information about starting these operations.

2

Press the AIR CLEAN button. (Fig. 5 

Y

)

The indicator lamp for the clean air indicator will light up.

Stopping the air clean operation

Press the AIR CLEAN button.

The indicator lamp for the clean air indicator will go out.

About the clean air indicator

The level of airborne contaminants in the room is monitored by the clean air indicator sensor
(Fig.  1 

F

)  and  displayed  in  the  clean  air  indicator. When  the  air  is  clean,  all  the  clean  air

indicator lamps will be green. As the air becomes dirty, the number of red indicator lamps will
increase.

After the power supply plug has been plugged in and the air cleaning operation has started, the clean air indicator sensor
will  perform  a  preparation  operation  for  approximately  3  minutes.  (The  same  will  occur  when  more  than  6  hours  have
passed after the operation has been stopped by the remote controller.) At this time, the sensor does not monitor the level of
airborne contaminants and the clean air indicator lamps will all be green. After 3 minutes of operation, the sensor will begin
to monitor the airborne contaminants and the condition of the air in the room will be displayed.

When the air cleaning operation is being performed, the number of illuminated red indicator lamps will either increase or
decrease according to the condition of the air in the room and the operation of the remote controller.

The clean air indicator does not respond to some contaminants.

Response by clean air indicator

: Tobacco  smoke,  incense,  aerosol  sprays  (insect  sprays,  cosmetic  sprays),  alcohol

(beverages, cooking, etc.), water vapor (from kitchen or bathroom) and others.

No response by clean air indicator

: Dust, pollen, mold spores, mite particles and others.

Air cleaning

During operation the unit produces a small amount of ozone that can be smelled.

When this unit is used in combination with the dust collection unit, white particles will become attached to the dust collec-
tion unit. When this happens, clean the dust collection unit as soon as possible. (Refer to page 14.)

The air cleaning unit cannot remove gases such as carbon dioxide and alcohol from the air. During operation, ventilate the
room often to prevent asphyxiation or suffocation.

If the intake grille is opened during operation, a safety device will stop the operation of the air cleaning unit. When this
happens, the operation lamp (red) on the main unit will and the timer lamp (green) will flash and the temperature monitor
will display 

. Use the START/STOP button on the remote controller to stop the operation, close the grille and then use the

START/STOP button to restart the operation.

Use the FAN CONTROL button to change the fan speed. (Refer to page 5.)  The air cleaning unit operates most effectively at
the highest fan speed.

When the fan is set to automatic, the fan speed will change among three fan speeds in response to the output of the clean
air indicator.  When the air in the room becomes clean, the air cleaning operation will be performed at the lowest fan speed.

The clean air indicator will flash to inform you that the periodic cleaning of the dust collection unit is required. (Refer to Air
Clean Check Function, page 14.)

ROOM

TEMP.

CLEAN

AIR

POLLUTED

AIR

OPERATION
TIMER
SWING

AIR CLEAN INDICATOR

HI-POWER

Clean air indicator

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Содержание AOH13PNCC

Страница 1: ...as normas seguintes By conformance with the standards the referenced products follows the provisions of the directives listed below In Übereinstimmung mit den Standards erfüllen die obengenannten Produkte den Verordnungen der unten aufgeführten EG Richtlinien Par leur conformité aux normes précitées les appareils de ce type répondent aux exigences des directives suivantes De acuerdo con estas norm...

Страница 2: ...UTION En 1 ROOM TEMP CLEAN AIR POLLUTED AIR OPERATION TIMER SWING AIR CLEAN INDICATOR HI POWER 1 2 34 5 6 7 8 9 0 A B C D E F H I J G PRESSIONE MASSIMA ASPIRAZIONE 800 kPa EMISSIONE 2 700 kPa REFRIGERANTE R22 1 050 g DIMENSIONI E PESO APPARECCHIO INTERNO Altezza Larghezza Profondità 290 815 215 mm Peso 11 5 kg netti APPARECCHIO ESTERNO Altezza Larghezza Profondità 535 695 250 mm Peso 35 kg netti Μ...

Страница 3: ...lly to maintain the set temperature and the tem perature is kept constant at all times SLEEP TIMER When the SLEEP timer button is pressed during heating mode the air conditioner s thermostat setting is gradually lowered during the period of operation during cooling mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit auto matically tu...

Страница 4: ...function to op erate incorrectly If this button is pressed during normal op eration the unit will switch to test opera tion mode and the Indoor Unit s OPERA TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation mode either press the TEST RUN button once again or press the START STOP button to stop the air conditioner Remote Control Unit Display ...

Страница 5: ...e side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the TIME ADJUST button Fig 6 Z Use the tip of a ball point pen or other small object to press the button 2 Use the SET TEMP SET TIME buttons Fig 5 Q to adjust the clock to the current time...

Страница 6: ...re To Set the Fan Speed Press the FAN CONTROL button Fig 5 T Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor...

Страница 7: ...ng Use to warm your room When Heating mode is selected the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In ord...

Страница 8: ...the operation of the remote controller The clean air indicator does not respond to some contaminants Response by clean air indicator Tobacco smoke incense aerosol sprays insect sprays cosmetic sprays alcohol beverages cooking etc water vapor from kitchen or bathroom and others No response by clean air indicator Dust pollen mold spores mite particles and others Air cleaning During operation the uni...

Страница 9: ...t To operate Hi power 1 Start the operation in any one of the following AUTO COOL HEAT DRY or FAN Refer to pages 5 and 6 for information about starting these operations 2 Press the HI POWER button Fig 5 X The indicator lamp for hi power red will light up To stop Hi power Press the HI POWER button The indicator lamp for hi power red will go out The unit will return to normal operation Hi power oper...

Страница 10: ...oor unit sTIMER Indicator Lamp green Fig 3 8 will light 3 Use the SET TEMP SET TIME button Fig 5 Q to ad just the desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about five seconds button Press to advance the time button Press to reverse the time About five seconds later the entire display will reappear To Use the Program timer 1 Press the...

Страница 11: ...T STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When...

Страница 12: ...in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 5 V Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow Direction Setting 1 2 3 During Cooling Dry modes 3 4 5 6 7 Duri...

Страница 13: ...en the air conditioner is operated with the controls on the Main Unit it will operate under the same mode as the AUTO CHANGEOVER mode se lected on the Remote Control Unit see page 6 During MANUAL AUTO operation the thermostat is automatically set at a standard temperature setting 24 C The fan speed selected will be AUTO and the airflow direction will be the standard direction cooling 1 heat ing 6 ...

Страница 14: ...ower tabs are returned properly to their holes in the panel 4 Close the Intake Grille Press on the four locations at the bottom of the grille to securely close the intake grille If the intake grille is not closed securely the temperature monitor will display a and the operation of the air cleaning unit will be stopped Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washi...

Страница 15: ...w shows the unit without the grille This is for explanatory purposes only The actual intake grille cannot be removed Grasp the handle of the dust collection unit Pull up shown as direction 1 and then pull down shown as direction 2 to remove Handle Cleaning the dust collection unit Wash with water and dry 1 Soak the dust collection unit in warm water 40 to 45 C for 10 to 15 minutes If the dust coll...

Страница 16: ...in the frame If the dust collection unit is not properly mounted the red operation lamp and green timer lamp will flash a will be displayed in the temperature monitor and the air cleaning opera tion will stop CLEANING THE PLASMA AIR CLEANING FILTER 2 Mount the air filter and close the intake grille Refer to page 13 After cleaning the dust collection unit if the red oper ating lamp and green timer ...

Страница 17: ...at a time Back of air filter Light regenerated deodorizing filter frame Top tabs Cleaning the light regenerated deodor izing filter 1 Dry the light regenerated deodorizing fil ter in direct sunlight Dry the light regenerated deodorizing filter in direct sunlight It is recommended that this filter be left in direct sun light for 6 hours Never wash the filter with water or other liquid Light regener...

Страница 18: ...temperature changes During Heating operation a sizzling sound may be heard occasional This sound is produced by the Automatic Defrosting operation Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner The operation of the air cleaning unit produces a small amount of ozone which can be smelled Duri...

Страница 19: ... This lamp will flash slowly after approximately 400 hours of op eration of the clean air indicator Stop the operation unplug the power cord and clean the dust collection unit and deodorizing filter This lamp will flash rapidly after approximately 500 hours of op eration of the clean air indicator The air cleaning operation will be stopped when this flashing occurs Make sure the operation is stopp...

Страница 20: ...If the intake grille is opened during operation a safety device will stop the operation of the air cleaning unit Use the remote con troller to stop the operation close the grille and then restart the operation Is the dust collection unit wet For safety reasons the safety device will stop the air cleaning operation if the dust collection unit is wet Use the remote con troller to stop the operation ...

Страница 21: ...age 3 Use of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily disconnect the Power Supply Plug reconnect it and then use the Remote Control Unit to resume operation Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transf...

Отзывы: