16
RECOMMENDED ADJUSTMENTS
To set the table-stop bolt:
1.
Loosen the two lock knobs
(Fig. 20).
See Fig.18
2.
Place a combination square
flat on the table
with
the heel of the square flat against the saw blade,
.
3.
Level the table until it is exactly 90° to the saw blade.
4.
Tighten the lock knobs.
See Fig. 19
5.
Adjust the height of the table-stop bolt
until it tou-
ches the underside of the table.
6.
Turn the jam-nut clockwise until it meets the table tilt
bracket
and tighten it.
7.
Loosen the lock knobs and make sure the table is rest-
ing on the table-stop bolt.
8.
Check the square and make sure the table is still at 90°
to the blade. If not, re-adjust the table-stop bolt.
See Fig. 20
9.
With the table set to 90º and the stop bolt at the cor-
rect height, make sure the table tilt angle indicator
pointer is set to read 0º.
10.
If the pointer needs to be adjusted, loosen the screw
on the pointer
of the front trunnion and adjust the
pointer to the 0 point on the scale. Then re-tighten the
screw to secure the pointer in place.
Never adjust the table angle while the bandsaw is run-
ning. Turn off power first.
1.
Loosen the two lock knobs
.
2.
Tilt the table until it is at the desired angle. (Refer to the angle
indicator under the bandsaw table.)
3.
Tighten the lock knobs to lock the table in position.
TILTING THE TABLE
The table can be tilted to any angle from 0° to 45° to the right, to allow for any type of bevel (or angle) cutting. Refer
to the table tilt angle indicator to set the angle of the table to the desired position.
Fig. 18
Fig. 19
Fig. 20
You will now be able to accurately return the table to the 90º position automatically without further adjustments and
scale reading for any angle other than 0 will also be accurate.
ADJUSTING THE 90º TABLE STOP AND RE-ALIGNING THE ANGLE POINTER
To ensure that your 90º cuts are square and that angled cuts are accurate with the angle indicator scale, the table
default position must be set to 90º to the blade and the angle indicator pointer must be set to read 0 when the table
is in the default (90º) position.
Содержание 90-125 M1