GM8802F-2 Field Mounting Transmitter
GM8802-F2110101
15
For example
Read command from address
01
in channel no.
1
:
02 30 31 31 52 57 54 30 31 0D 0A
Correct response:
02 30 31 31 52 57 54 40 61 30 30 30 31 33 32 35 36 0D 0A
Means
:
AD
start
、
normal
、
positive weight
、
nonzero
、
stable
;
weight
:
132
2
)
Read state and weight from all of channels
Read command
:
STX
Address
A
R
W
T
CRC
CR
LF
Correct response
:
STX
Address
Channel no.
R W
T
Channel no.1~2
state and weight
CRC
CR LF
Here
:
A
——
1bit
,
41H
Channel no.1~2 state and weight
——
2×8bits
,
2bits state and 6bits weightfor every
channels. Please see signal channel instruction.
For example:
Read command from address
01
in all of channels
:
Read command
:
02 30 31 41 52 57 54 31 37 0D 0A
Correct response
:
02 30 31 41 52 57 54 40 61 30 30 30 32 33 30 40 63 20 20 4F 46 4C 20
30 33 35 34 0D 0A
Means
:
Channel no.
1
:
AD
start, normal, positive weight, nonzero, stable
;
weight
:
230
Channel no.
2
:
AD
start, normal, positive weight, overflow, nonzero, stable
;
weight
:
OFL
3
)
Read other parameters
The data format of read command and response are same. Please see parameter table to
read and write.
Read command
:
STX
Address
Channel no.
R
Parameter code
CRC
CR
LF
Correct response
:
STX
Address Channel no.
R
Parameter code Value
CRC
CR
LF
Here
:
Parameter code
——
2bits
,
please refer Character 5.2.1.1 “Parameters code table”.
Value
—— please refer Character 4“Parameter table”.
For example:
Read stable range from address
01
in Channel no.
1
:
Read command
:
02 30 31 31 52 4D 52 38 39 0D 0A
Correct response:
02 30 31 31 52 4D 52 35 34 32 0D 0A
Means: present stable range in Channel no.
1
:
5
www.zemicusa.info